A hull potential test measures how well a boat's anodes protect its underwater metals. A silver/silver chloride reference electrode hangs in the water, a multimeter reads the voltage between it and each metal, and the reading is compared with a protection range for the hull type. Southern Boating's corrosion article gives the method and ranges used below. It also shows whether the boat is isolated from the shore power ground.
Setting up
The test is done afloat, in calm water, with shore power unplugged at the boat, not just switched off, and no equipment running.
- Connect the reference electrode, on at least 20 feet of marine-grade wire, to the multimeter's negative terminal. Set the meter to DC volts, or millivolts if it has them.
- Connect the positive lead to the metal being measured. On a bonded boat, use a clean point on the bonding system, such as a bolt, bus bar or terminal, cleaned with an abrasive pad if needed.
- Lower the electrode about two feet below the surface, clear of the hull.
- Read and record, then repeat for each underwater metal.
The article recommends measuring every underwater metal on its own even when the boat is bonded, since a difference between them points to a bonding fault. The propeller and shaft need their own reading, because their path through the oil-filled gearbox is a poor conductor and shaft brushes rarely reach the one ohm the bonding connection should have.
Protection ranges in seawater
| Boat | Protected range |
|---|---|
| Fibreglass, common underwater metals other than aluminium | -750 to -1,100 mV |
| Timber hull, metals other than aluminium | -550 to -600 mV |
| Steel hull | -850 to -1,100 mV |
| Aluminium | No more negative than -1,100 mV |
Southern Boating notes the fibreglass range is more conservative than ABYC's. The rule behind all of them: an anode must drive a metal at least 200 mV more negative than its resting voltage. Resting voltages it gives include silicon bronze at -260 to -290 mV, aluminium alloys -760 to -1,000 mV, and 316 stainless in still water -430 to -550 mV.
Over-protection
Most metals aren't harmed by too much protection. Aluminium is the exception: the alkaline solution that over-protection creates attacks it, which is why its limit is -1,100 mV. On timber boats, the same alkali attacks the wood around bonded fittings. Anodes that hardly wear are as much a warning as anodes that vanish, the article adds: it's a sign they aren't working.
The shore power check
With the readings done, plug in the shore power cord and leave the power off. If any reading moves by more than a few millivolts, the boat isn't isolated from the dock's ground and needs a galvanic isolator, or the one fitted isn't working.
For surveyors
Record the hull type, the water, whether the boat was plugged in, and each metal's reading in millivolts. With Axsail, say "reference cell, bonding bus minus 820, shaft minus 540, cord plugged in moves 40" and the readings land as a table with findings on the shaft and the isolation.