Axsail
SURVEY TEST METHODS · ELECTRICAL AND GAS

Thermal imaging on a boat survey: electrical connections, engines and wet laminate

UPDATED 17 NOVEMBER 2026 · 4 SOURCES

How surveyors use a thermal camera on a boat: hot electrical connections, cooling faults and active thermography for wet core, with its limits.

AT A GLANCE
Thermal imaging
MEASURES
Surface temperature differences: hot connections and components, and laminate that heats or cools at a different rate
TOOLS
A radiometric thermal camera; a heat source for active thermography of laminates
WHEN TO USE
Electrical panels and battery banks under load, engines on the sea trial, and composite hulls and decks where moisture or voids are suspected
READ WITH
Emissivity of the surfaces, a visible-light photo of the same spot, and moisture meter or percussion results

Thermal imaging on a boat survey finds problems by temperature. A connection with high resistance runs hotter than its neighbours, a blocked cooling circuit shows the wrong colour, and wet or void laminate heats and cools at a different rate from sound laminate. The technique and its limits below come from Power & Motoryacht, surveyor and thermographer Jack Allinson, and Panbo.

Electrical systems

Power & Motoryacht explains why it works: poor connections increase resistance and create more heat than good ones. Allinson's paper shows two examples a visual check missed. One was a wire in a distribution panel bundle much hotter than the rest, tripping its breaker. The other was a shore power Y adapter with heat building in one leg, traced to corroded pins.

To get a fair picture:

  1. Put the circuit under load, as Panbo did with a large load on a battery bank.
  2. Scan panels, battery terminals and crimps, the shore power inlet and the cord.
  3. Compare like with like. Panbo notes ABYC electrical study material suggests a difference of less than 25°F between connections is acceptable.
  4. Save radiometric images, so spot temperatures can be added and checked later.

Engines and machinery

Power & Motoryacht's rule of thumb: if something that should be cool, such as the raw water pump, shows hot, or something that should be hot, such as raw water leaving the heat exchanger, shows cool, investigate. Allinson's paper includes an engine overheating case traced along the raw water and closed cooling circuits with the camera. Motors, bearings, gears and refrigeration are on his list of mechanical uses.

Hulls and decks: active thermography

Laminates need a temperature change to show anything. In Power & Motoryacht's hull survey, the surveyor warmed the hull so slightly it was barely noticeable to the touch, then recorded it cooling. Wet areas cool more slowly than dry ones and voids appear hotter, and the rate of change matters more than the absolute temperature. Core blocks, solid areas around through-hulls and old repairs all showed, and a dark band along the keel pointed to water in the sandwich, which core samples then confirmed.

Limits and training

  • Emissivity. Two materials at the same temperature can look different on the camera. Allinson says a trained thermographer knows how to compensate.
  • Training. He advises at least Level I thermography certification for anyone selling thermal surveys.
  • A snapshot. Power & Motoryacht points out that a one-time scan only shows the boat as it is that day.
  • Confirmation. The Power & Motoryacht surveyor recommended cutting core samples to confirm what the images showed, and carries a moisture meter alongside the camera.

For surveyors

Report each anomaly with the thermal image, a visible-light image of the same spot, the load at the time and the temperature difference. Pair laminate findings with percussion testing and moisture readings. With Axsail, say "main panel, bilge pump breaker terminal 31 degrees above its neighbours at full load" as you take the image, and both photos go on the finding.

Findings to look for

Each page shows how the defect is found, what decides the grade and example findings written up at A, B and C.

ELECTRICAL

Overheated shore power inlet

Why shore power inlets and cord ends overheat and burn, the infrared temperature check a former ABYC technical VP recommends, what to look for behind the inlet, and three example findings graded A, B and C.

How to find and write it up
HULL AND STRUCTURE

Wet deck core

How water gets into a cored deck, how a surveyor maps it with a moisture meter and a hammer, which readings to trust, what recoring costs and three example findings graded A, B and C.

How to find and write it up
ENGINE AND FUEL

Engine overheating

Why marine diesels overheat, chronic against acute overheating, the order to check the cooling system in, the temperature test for a blocked exhaust elbow, what a surveyor checks and three example findings graded A, B and C.

How to find and write it up
ELECTRICAL

Missing overcurrent protection

Why an unfused battery cable is a fire risk, the ABYC E-11 rule surveyors check against, which fuse types suit which battery banks, what the fix costs and three example findings graded A, B and C.

How to find and write it up

Frequently asked

What can a thermal camera find on a boat?

Power & Motoryacht lists overheated electrical connections, cooling faults such as a raw water pump running hot or a heat exchanger outlet running cool, and, with active thermography, voids, delamination and water in composite hulls and decks.

How hot is too hot for an electrical connection?

Panbo's writer, reviewing ABYC electrical certification study material, notes it suggests temperature differences of less than 25°F between connections are acceptable. A connection much hotter than its neighbours under the same load points to resistance.

Can thermal imaging find wet core in a fibreglass hull?

Yes, with active thermography. Power & Motoryacht describes a surveyor warming the hull slightly and recording it as it cools: wet areas cool more slowly than dry ones and voids appear hotter. Absolute temperature matters less than the rate of change.

Do you need training to use a thermal camera on surveys?

Jack Allinson, a Level III certified thermographer, advises checking that a surveyor offering thermography holds at least Level I certification, because emissivity and reflections can fool an untrained eye.

Your full survey report, minutes after the walk-round

Dictate as you inspect. Axsail builds the findings and the report for your signature

Start free

More test methods

All test methods
ELECTRICAL AND GAS

Boat battery test

How to test a boat battery, from Trojan, Crown and Lifeline: rested voltage, hydrometer readings, load tests and a full capacity test, and which to trust.

Read the method
ELECTRICAL AND GAS

LPG gas leak test

How a boat's LPG system is checked for leaks: the test point or bubble detector the Boat Safety Scheme requires, the tightness test and regulator lock-up.

Read the method
ELECTRICAL AND GAS

Hull potential test

How to run a hull potential test with a silver/silver chloride reference electrode: setup, protection ranges by hull type and the shore power isolation check.

Read the method
HULL AND STRUCTURE

Percussion test (hammer sounding)

How surveyors sound a fibreglass hull for delamination: which hammer or coin to use, tapping every 2 to 3 inches, and telling a dull thud from a bulkhead.

Read the method
HULL AND STRUCTURE

Ultrasonic thickness testing

Ultrasonic hull thickness testing on steel boats and narrowboats: gauge or A-scan, mill tolerance, wastage limits and the 4 mm insurance rule.

Read the method
HULL AND STRUCTURE

Inclining experiment

What an inclining experiment is for, how it is run under the MCA and Red Ensign codes, the 8 weight movements and when a lightweight check will do.

Read the method

Report templates

FREE TEMPLATE · WORD

Pre-purchase survey

Free Word template for a recreational boat or yacht pre-purchase survey report: each section explained, with example wording and findings graded by urgency.

Open template