Axsail
SURVEY TEST METHODS · ELECTRICAL AND GAS

LPG gas leak test on a boat: tightness testing, test points and bubble detectors

UPDATED 17 NOVEMBER 2026 · 2 SOURCES

How a boat's LPG system is checked for leaks: the test point or bubble detector the Boat Safety Scheme requires, the tightness test and regulator lock-up.

AT A GLANCE
LPG gas leak test
MEASURES
Whether the LPG system holds pressure with the appliances off: any drop or bubble means a leak
TOOLS
A suitable pressure gauge on the system's test point, or the bubble leak detector in the cylinder locker
WHEN TO USE
Every survey of a boat with gas, before using any gas appliance on board
READ WITH
The BSS tightness test procedure, and the boat's locker and hose condition

An LPG gas leak test on a boat checks that the system holds pressure with every appliance off. The Boat Safety Scheme requires each LPG system to have a way to test it, a test point or a bubble leak detector, and to pass a tightness test with no leak. If the test can't be done, the item counts as non-compliant until it is. The checks below are from Part 7 of the BSS Core Examination Checking Procedures.

The means to test

BSS check 7.12.1 requires one of these, readily accessible:

Means Where
Proprietary test point In the pipework
Proprietary test point On an appliance
Bubble leak detector In the cylinder locker or housing

A boat with none of them can't be tightness tested, and fails the check.

The tightness test

Check 7.12.2 says the system must be free of leaks when tested to the appropriate procedure in the BSS appendices, one of which uses a pressure gauge on a test point. The checking procedures cover these outcomes:

  • No leak. The item passes.
  • Leak found. The examiner follows the BSS actions for a leak, which can include a hazardous boat notification under the criteria in the appendices.
  • Test not completed. Marked "not verified", non-compliant until tightness is shown, with the reason recorded.
  • Regulator doesn't lock up. On a gauge test, a regulator that doesn't lock up within industry tolerances is noted on the warning notice, with its age if over 10 years. The BSS guides owners to have it tested by a Gas Safe registered LPG in boats installer and recommends replacing regulators over 10 years old.

Checks around the test

The same part of the BSS checks covers the installation the test depends on:

  • the cylinder locker drain outlet above the normal laden waterline, sized from 12 mm for 1 to 18 kg of gas up to 19 mm for 38 kg and over
  • the locker opening outside the engine and battery spaces
  • LPG pipe at least 75 mm from the exhaust
  • low pressure hose to BS EN 16436 or BS 3212 type 2

Outside the UK

US charter boats carrying passengers for hire follow 46 CFR 25.45-2: LPG cooking systems meet ABYC A-1 or chapter 6 of NFPA 302, with odorised gas.

For surveyors

Record how the system was tested, the test point or bubble detector, and the result, and say so plainly if no test was possible. With Axsail, say "gas tightness test at the cooker test point, held, no drop; regulator dated, eleven years old" and the finding goes into the report with the BSS reference and a recommendation to replace the regulator.

Findings to look for

Each page shows how the defect is found, what decides the grade and example findings written up at A, B and C.

GAS AND SAFETY

Out of date gas hose

Why flexible LPG hoses on boats are replaced at five years from the date printed on them, where to find the date, the BS 3212 rating, what else a surveyor checks on the gas line, and three example findings graded A, B and C.

How to find and write it up
GAS AND SAFETY

LPG locker drain

Why propane sinks and a gas locker has to drain overboard, what ABYC A-1 asks of LPG lockers, what a surveyor checks, the common faults and three example findings graded A, B and C.

How to find and write it up
GAS AND SAFETY

No gas detector

Why a boat with an LPG cooker needs a gas detector and solenoid shut-off, where the sensor goes, what to do in a leak, what a surveyor checks and three example findings graded A, B and C.

How to find and write it up

Frequently asked

How do you check a boat's gas system for leaks?

The Boat Safety Scheme requires every LPG system to have a readily accessible test point in the pipework or on an appliance, or a bubble leak detector in the cylinder locker. The system is then tightness tested to the BSS procedure and must show no leak.

What happens if a BSS examiner can't complete the gas tightness test?

The BSS checking procedures say the item is marked not verified and treated as non-compliant until tightness is verified, with the reason recorded.

When should a boat's gas regulator be replaced?

If the regulator doesn't lock up within industry tolerances during a gauge test, the BSS guides owners to have it tested by a Gas Safe registered LPG in boats installer, and recommends replacing regulators over 10 years old.

Which standard covers LPG on US charter boats?

46 CFR 25.45-2 requires LPG cooking systems on vessels carrying passengers for hire to meet ABYC A-1 or chapter 6 of NFPA 302, with odorised gas and cylinders marked and mounted to ABYC A-1.

Your full survey report, minutes after the walk-round

Dictate as you inspect. Axsail builds the findings and the report for your signature

Start free

More test methods

All test methods
ELECTRICAL AND GAS

Boat battery test

How to test a boat battery, from Trojan, Crown and Lifeline: rested voltage, hydrometer readings, load tests and a full capacity test, and which to trust.

Read the method
ELECTRICAL AND GAS

Hull potential test

How to run a hull potential test with a silver/silver chloride reference electrode: setup, protection ranges by hull type and the shore power isolation check.

Read the method
ELECTRICAL AND GAS

Thermal imaging

How surveyors use a thermal camera on a boat: hot electrical connections, cooling faults and active thermography for wet core, with its limits.

Read the method
HULL AND STRUCTURE

Percussion test (hammer sounding)

How surveyors sound a fibreglass hull for delamination: which hammer or coin to use, tapping every 2 to 3 inches, and telling a dull thud from a bulkhead.

Read the method
HULL AND STRUCTURE

Ultrasonic thickness testing

Ultrasonic hull thickness testing on steel boats and narrowboats: gauge or A-scan, mill tolerance, wastage limits and the 4 mm insurance rule.

Read the method
HULL AND STRUCTURE

Inclining experiment

What an inclining experiment is for, how it is run under the MCA and Red Ensign codes, the 8 weight movements and when a lightweight check will do.

Read the method

Standards to check against

BSS EXAMINATION CHECKING PROCEDURES

BSS Core Examination Checking Procedures

Boat Safety Scheme requirements for private boats, part by part: fuel, electrics, extinguishers, CO alarms and LPG, with the figures examiners measure.

What surveyors check
ABYC A-1

Liquefied Petroleum Gas (LPG) Systems

What ABYC A-1 asks of propane (LPG) systems on boats, the gas locker and drain rules, cylinders, solenoids and detectors, what a surveyor checks and how to cite A-1 in a finding.

What surveyors check
NFPA 302

Fire Protection Standard for Pleasure and Commercial Motor Craft

What NFPA 302 covers on pleasure and commercial boats under 300 gross tons, fire, explosion and carbon monoxide hazards, the latest additions on lithium batteries and engine compartment detection, and when surveyors cite it.

What surveyors check

Report templates

FREE TEMPLATE · WORD

Boat Safety Scheme pre-examination check

A free Boat Safety Scheme checklist in Word for narrowboats and private boats: fuel, batteries, extinguishers, CO alarms and the gas locker, by BSS part.

Open template