An LPG gas leak test on a boat checks that the system holds pressure with every appliance off. The Boat Safety Scheme requires each LPG system to have a way to test it, a test point or a bubble leak detector, and to pass a tightness test with no leak. If the test can't be done, the item counts as non-compliant until it is. The checks below are from Part 7 of the BSS Core Examination Checking Procedures.
The means to test
BSS check 7.12.1 requires one of these, readily accessible:
| Means | Where |
|---|---|
| Proprietary test point | In the pipework |
| Proprietary test point | On an appliance |
| Bubble leak detector | In the cylinder locker or housing |
A boat with none of them can't be tightness tested, and fails the check.
The tightness test
Check 7.12.2 says the system must be free of leaks when tested to the appropriate procedure in the BSS appendices, one of which uses a pressure gauge on a test point. The checking procedures cover these outcomes:
- No leak. The item passes.
- Leak found. The examiner follows the BSS actions for a leak, which can include a hazardous boat notification under the criteria in the appendices.
- Test not completed. Marked "not verified", non-compliant until tightness is shown, with the reason recorded.
- Regulator doesn't lock up. On a gauge test, a regulator that doesn't lock up within industry tolerances is noted on the warning notice, with its age if over 10 years. The BSS guides owners to have it tested by a Gas Safe registered LPG in boats installer and recommends replacing regulators over 10 years old.
Checks around the test
The same part of the BSS checks covers the installation the test depends on:
- the cylinder locker drain outlet above the normal laden waterline, sized from 12 mm for 1 to 18 kg of gas up to 19 mm for 38 kg and over
- the locker opening outside the engine and battery spaces
- LPG pipe at least 75 mm from the exhaust
- low pressure hose to BS EN 16436 or BS 3212 type 2
Outside the UK
US charter boats carrying passengers for hire follow 46 CFR 25.45-2: LPG cooking systems meet ABYC A-1 or chapter 6 of NFPA 302, with odorised gas.
For surveyors
Record how the system was tested, the test point or bubble detector, and the result, and say so plainly if no test was possible. With Axsail, say "gas tightness test at the cooker test point, held, no drop; regulator dated, eleven years old" and the finding goes into the report with the BSS reference and a recommendation to replace the regulator.