Ultrasonic thickness testing measures how much steel is left in a hull plate by timing a sound pulse through it. On steel boats and narrowboats it's the core of an out of water survey, and often what an insurer's renewal hangs on. The harder part is judging the number: there's no agreed wastage limit for small steel craft, and a low reading isn't always loss. The guidance below is from an IIMS discussion paper and Practical Sailor.
Gauge or A-scan
| Instrument | What it gives | Practical Sailor's view |
|---|---|---|
| Basic thickness gauge | One number, the largest echo | Acceptable for new steel or gross estimates of corrosion |
| A-scan or C-scan flaw detector | All the echo data, as a wave form or a plan view | Can find hidden corrosion on the far surface before it weakens the plate |
| Pit gauge | Depth of a single pit | Better than ultrasound for pits smaller than the transducer |
Practical Sailor notes that corrosion on the far side scatters the sound, so the echo goes weak and broad, which an A-scan shows and a simple gauge misses.
Taking readings
The IIMS paper's points for surveyors:
- Framing is usually out of reach on a narrowboat, so the plating carries the assessment.
- Pitting is widespread on boats with basic blacking, and base plating is hard to clean and reach fully at most docks.
Reading the number
Mill tolerance. Steel plate is supplied with a tolerance. Under EN 10029 tolerance class D, 6 mm plate can be 6 mm plus or minus 0.75 mm, so a 5.25 mm reading may be as built, not wastage. Plates can also taper.
What was it built to? The paper says the current narrowboat convention is 10/6/4: 10 mm base, 6 mm sides, 4 mm superstructure. Older boats were built to many other specifications, some all-over 3 mm. Trade association guidance and Dave Gerr's scantling formulae both put the minimum effective thickness at about 3 mm.
Wastage limits. Surveyors split between a minimum thickness and a percentage loss. Class societies use 20% and 25% wastage for ships, and the paper notes surveyors have been challenged legally for not requiring repair above 20%. Applied to a 10 mm base, 20% means repairing any pit over 2 mm. The paper suggests 25% of the minimum design thickness as a more proportionate trigger.
The 4 mm rule. Many insurers ask for at least 4 mm at survey, and their requirements differ. The paper calls the 4 mm figure unhelpful and argues it isn't based on design need.
For surveyors
Take readings on a grid by location so the next survey can compare. Write down the original specification if known, the instrument and mode used, and each reading with its location, and say which standard you judged against, whether the insurer's minimum or a percentage loss. With Axsail, dictate as you go, "base plate, aft third, port side, 8.6, pit 2.1 deep", and the readings come out as a table in the out of water survey report.