The Boat Safety Scheme requirements are the check items in the BSS Core Examination Checking Procedures, the book every examiner works from. Each check is a question the boat has to answer yes to. The procedures say examiners must use a checklist on every examination so no check is missed. The boat's owner is responsible for keeping it compliant between examinations, as a condition of the licence.
The parts of the examination
| Part | What it covers | Examples from the checks |
|---|---|---|
| 2 | Permanently installed fuel systems and fixed engines | Fill points that keep overflow out of the boat, tank vents at least 9.5 mm bore, an emergency shut-off in every fuel feed line |
| 3 | Electrical systems | Unsealed batteries ventilated to outside, batteries secure and away from petrol and LPG parts, isolators in reach |
| 4 | Electrical propulsion | Motor, controller and charging gear ventilated and in good condition |
| 5 | Outboards, portable fuel systems and spare fuel | Spare petrol limited to the permitted number and capacity, stored so vapour can't enter the boat |
| 6 | Fire extinguishing, escape and CO alarms | Extinguisher numbers and ratings by length, a fire blanket for fixed cooking, at least one CO alarm |
| 7 | LPG systems | Cylinders stored so leaking gas goes overboard, locker drains above the waterline, hoses and a tightness test |
| 8 | Appliances and flues | Flame supervision devices, heat damage near flues, fixed ventilation |
| 9 | Pollution prevention | Oil leaks from the engine caught in a tray or oil-tight area, a closable valve on any toilet discharge line that runs overboard |
Part 10 applies to hire boats only.
Requirements and Advice checks
Each check carries a status. R is a Requirement. A is an Advice check, which on a privately owned or managed boat doesn't stop the certificate. The procedures say there are 14 Advice checks within Parts 3, 6 and 8, and that all of them are mandatory Requirements for hire boats. Two of them are the means of escape from each accommodation space and fixed ventilation.
The BSS says Requirements target the risks of fire and explosion, along with pollution of the waterway. Failed Advice items may still matter to the boat's insurance.
The figures examiners measure
| Check | Figure |
|---|---|
| Fuel tank vent line (2.3.2) | Minimum internal diameter 9.5 mm |
| Fuel hose for diesel lines | Marked for the fuel and as fire resistant, to BS EN ISO 7840 or an equivalent |
| Fire extinguishers (6.1.1) | Each rated at least 5A/34B; two to three by length, see BSS fire extinguishers |
| Fire blanket (6.2) | To BS EN 1869 or BS 6575, within about 2 m of the main cooking appliance |
| CO alarm (6.4.1) | At least one where there's accommodation, within 10 m of any door linking accommodation spaces |
| Cylinders in an open location (7.1.1) | No opening into the boat or source of ignition within 0.5 m |
| LPG pipe and hose (7.8.7) | At least 75 mm from exhaust and flue components |
| Low-pressure LPG hose | Marked to BS EN 16436 or BS 3212 type 2 |
Gas on residential boats
On residential boats, work on the gas system falls under the Gas Safety (Installation and Use) Regulations, the BSS says, and has to be done by a Gas Safe registered engineer competent on LPG in boats. A bubble leak detector isn't a BSS requirement, but the BSS strongly recommends one in the gas locker.
For surveyors
The BSS procedures give UK inland surveyors a published yardstick that ISO and ABYC references don't cover, and citing the check number makes a finding easy to verify. "Fire extinguishers: two fitted, combined rating below the BSS minimum for a boat of this length (check 6.1.1)" is clearer to an owner than "insufficient extinguishers". The BSS checklist follows these parts, and the BSS certificate page covers validity and renewal. With Axsail, say the check number with the observation and it's written into the finding.