Axsail
FINDINGS LIBRARY · GAS AND SAFETY

Boat Safety Scheme fire extinguishers: how many, what rating, where they go and how surveyors write it up

UPDATED 15 NOVEMBER 2026 · 3 EXAMPLE FINDINGS · 2 SOURCES

Boat Safety Scheme fire extinguisher requirements: number and combined rating by boat length, the 5A/34B minimum, fire blankets and example findings.

AT A GLANCE
BSS fire extinguishers short
USUAL GRADE
A for a boat with fixed cooking and no working extinguisher. B for a combined rating below the BSS table or an extinguisher in poor condition. C for extinguishers out of view with no label
FOUND WITH
Finding every extinguisher on board, reading each one's fire rating and certification mark, checking the pin, gauge and hose, and noting where each is mounted
JUDGED AGAINST
BSS check 6.1.1, which sets two extinguishers for boats up to 11 m and three over 11 m, each rated at least 5A/34B, with a minimum combined rating by length
REPAIR COST
The price of one or two certified extinguishers and a fire blanket

The Boat Safety Scheme sets fire extinguishers by the boat's length and by combined fire rating, so two small extinguishers can fail on a long boat. On a survey the check takes a few minutes: find every extinguisher, read the ratings off the labels and add them up.

How many extinguishers the BSS asks for

BSS check 6.1.1 sets the minimum:

Length of boat Minimum number Minimum combined fire rating
Under 7 m (23 ft) 2 10A/68B
7 to 11 m (23 to 36 ft) 2 13A/89B
Over 11 m (36 ft) 3 21A/144B

The number can drop by one 5A/34B extinguisher on a boat that has no internal combustion engine or no fuel-burning appliance, the procedures say. Fuel-burning appliances include those running on LPG, diesel, paraffin, spirit and solid fuel.

What counts as a suitable extinguisher

Each one needs a rating of 5A/34B or more and at least one accredited third-party certification mark. The procedures list the signs of poor condition that fail it:

  • a missing safety pin
  • dents, gouges, significant rust or other corrosion
  • a perished hose
  • the pressure gauge in the red sector, or damage to the trigger from sun or heat

Age alone isn't one of them: the procedures say a unit past the maker's warranty date isn't an indicator of poor condition. That differs from the US rule on expired fire extinguishers, where disposable units leave service by age.

Where they go

Check 6.1.2 asks for extinguishers to be readily accessible, spread around the boat next to escape routes, and never placed so you'd reach over a cooker to get one. Check 6.1.3 asks for them to be in open view with lids and curtains closed, or for a label in view showing where they are. The BSS strongly recommends fixed brackets, though they aren't a requirement on private boats.

A boat with permanently installed cooking needs a fire blanket to BS EN 1869 or BS 6575, within about 2 m of the main cooking appliance, under check 6.2.

What decides the grade

What happens if a fire starts tomorrow. No working extinguisher on a boat with a fixed cooker is an A. A complement below the table, or a unit that fails on condition, is a B. Extinguishers that are fine but hidden are a C.

BSS fire extinguishers short: example findings

The same defect written up at each grade, the way Axsail writes it from what the surveyor says on board. The grade follows what was found, so use these as wording, then grade what you see.

SAFETY EQUIPMENTA
Galley and saloon

One extinguisher aboard, gauge reading in the red and safety pin missing. Fixed LPG hob in the galley; no fire blanket. Boat 17 m.

Recommendation: Fit at least three certified extinguishers with a combined rating of 21A/144B or more, and a fire blanket within about 2 m of the hob, before the boat is next used.

SAFETY EQUIPMENTB
Saloon and stern cabin

Two extinguishers, each rated 5A/34B, on a 10 m boat. Combined rating 10A/68B, below the 13A/89B the BSS sets for 7 to 11 m.

Recommendation: Replace one extinguisher with a higher rated unit, or add a third, to reach at least 13A/89B combined before the next BSS examination.

SAFETY EQUIPMENTC
Forward cabin

Extinguisher in a closed cupboard with no label showing where it is. Rating and condition satisfactory.

Recommendation: Mount the extinguisher in view near the forward exit, or fit a fire extinguisher location label on the cupboard door.

ASafety. Safety or compliance deficiency. Fix before the vessel is next underway.
B12 months. Deficiency that needs timely attention. Fix within about 12 months.
CRoutine. Note or observation, cosmetic or maintenance. Routine maintenance at the owner's convenience.

Photos to take

Each extinguisher's label with the rating and certification mark, the gauge, and where it's mounted, plus the fire blanket by the hob. With Axsail, read the rating out as you photograph each one and the finding totals them against the boat's length.

Writing it up

List each extinguisher with its location, rating and condition, then give the combined rating against the BSS figure for the boat's length. Cite check 6.1.1 so the owner can look it up. The BSS checklist lets the owner check the rest before the examination.

Frequently asked

How many fire extinguishers does a boat need for the Boat Safety Scheme?

Two for a boat under 7 m or from 7 to 11 m, and three for a boat over 11 m, per BSS check 6.1.1. Each must be rated at least 5A/34B, and together they must reach 10A/68B, 13A/89B or 21A/144B for those lengths.

What fire extinguisher rating does the BSS need?

Each extinguisher must have an individual rating of 5A/34B or more and carry an accredited third-party certification mark. The BSS procedures say examiners don't check the manufacturing standard, so BS 5423 and BS EN 3 units both count.

Does an out-of-date extinguisher fail the BSS?

Not on its date alone. The BSS procedures say an extinguisher past the maker's warranty date isn't an indicator of poor condition. A missing pin, dents, corrosion, a perished hose or a gauge in the red sector fails it.

Do I need a fire blanket for the BSS?

Yes, if the boat has permanently installed cooking. Check 6.2 asks for a blanket marked to BS EN 1869 or BS 6575, within about 2 m of the main cooking appliance and not mounted over it. A microwave doesn't count as fixed cooking.

Your full survey report, minutes after the walk-round

Dictate as you inspect. Axsail builds the findings and the report for your signature

Start free

Standards it's judged against

BSS EXAMINATION CHECKING PROCEDURES

BSS Core Examination Checking Procedures

Boat Safety Scheme requirements for private boats, part by part: fuel, electrics, extinguishers, CO alarms and LPG, with the figures examiners measure.

What surveyors check

Related findings

Findings library
GAS AND SAFETY

Expired fire extinguishers

When a disposable marine fire extinguisher expires under the US Coast Guard rule, how to read the date stamp, what makes an extinguisher good and serviceable, and three example findings graded A, B and C.

How to find and write it up
GAS AND SAFETY

BSS CO alarm missing or failed

Boat Safety Scheme carbon monoxide alarm requirements: one per boat with accommodation, the 10 m door rule, BS EN 50291 and example findings.

How to find and write it up
GAS AND SAFETY

LPG locker drain

Why propane sinks and a gas locker has to drain overboard, what ABYC A-1 asks of LPG lockers, what a surveyor checks, the common faults and three example findings graded A, B and C.

How to find and write it up
GAS AND SAFETY

No CO alarm

Where a boat needs carbon monoxide detectors under the revised ABYC A-24, which detectors qualify, where not to fit them, what a surveyor checks and three example findings graded A, B and C.

How to find and write it up
GAS AND SAFETY

Expired life raft

How often a yacht life raft needs servicing, what ISO 9650 and the makers ask, what a service costs, when replacing beats servicing, and three example findings graded A, B and C.

How to find and write it up
GAS AND SAFETY

Out of date gas hose

Why flexible LPG hoses on boats are replaced at five years from the date printed on them, where to find the date, the BS 3212 rating, what else a surveyor checks on the gas line, and three example findings graded A, B and C.

How to find and write it up

Report templates with this finding

FREE TEMPLATE · WORD

Boat Safety Scheme pre-examination check

A free Boat Safety Scheme checklist in Word for narrowboats and private boats: fuel, batteries, extinguishers, CO alarms and the gas locker, by BSS part.

Open template
FREE TEMPLATE · WORD

Pre-purchase survey

Free Word template for a recreational boat or yacht pre-purchase survey report: each section explained, with example wording and findings graded by urgency.

Open template