The Boat Safety Scheme asks for at least one carbon monoxide alarm on every boat with accommodation, and it fails alarms that are out of date, uncertified or hidden. The checks sit in Part 6 of the BSS procedures, alongside fire extinguishers. On a survey they take a few minutes with a tape measure.
How many alarms and where
| Check | What it asks |
|---|---|
| 6.4.1 | At least one CO alarm on any boat with accommodation, within 10 m of any door linking accommodation spaces. One is enough for a single open-plan space of any size |
| 6.4.2 | An alarm in each accommodation space with a solid fuel stove, where the boat has berths. Advice on private boats, Requirement on hire boats |
| 6.4.3 | In open view with doors and curtains in place; certified to BS EN 50291 or equivalent; a test button |
| 6.4.4 | Good condition, within the maker's replacement date, passes its test |
The BSS calls 6.4.1 a minimum, meant to give a warning heard throughout the boat when CO comes in from outside. For better protection it points owners to the alarm maker's advice on number and placement.
Which alarms pass
The procedures name the main UK certification bodies as BSI and LPCB. For BRK, Dicon, Ei Electronics, Fire Angel, FireHawk, First Alert, Honeywell and Kidde, certification to BS EN 50291 can be assumed. Other makes may need lifting off their base to read the approval mark, with the owner's permission. The BSS recommends alarms marked BS EN 50291-2, which are tested for the harsher conditions on boats, though that isn't a requirement.
Replacement dates catch out many boats. If the label says "replace 10 years after installation" and nobody wrote the installation date on it, the examiner takes 10 years from the manufacturing date. The US equivalent, under ABYC A-24, is on no CO alarm.
How a surveyor checks it
Count the accommodation spaces and the doors between them. Find each alarm and measure to the furthest linking door. Read the label for the standard and the dates, check it's in view with doors shut, and press the test button. Note any solid fuel stove and which space it's in.
What decides the grade
Whether someone could be asleep aboard without a warning. No alarm on a boat with accommodation and a stove or engine is an A. An alarm that's out of date, uncertified, damaged or fails its test is a B. A working, certified alarm out of view is a C.