No galvanic isolator: why surveyors flag it and what fitting one costs

UPDATED 5 NOVEMBER 2026 · 3 EXAMPLE FINDINGS · 3 SOURCES

How the shore power earth links your boat's underwater metals to every boat on the dock, what a galvanic isolator does, what ABYC A-28 asks for, what one costs and three example findings graded A, B and C.

AT A GLANCE
No galvanic isolator
USUAL GRADE
B for shore power with no isolator or isolation transformer. A when the shore earth is missing or disconnected instead. C for checking an older isolator
FOUND WITH
Tracing the green earth wire from the shore power inlet, reading the label on any isolator, and looking at the anodes and underwater metals
JUDGED AGAINST
ABYC A-28 for galvanic isolators, which covers fail-safe units that need no monitor. Isolators are rated 30 A, 50/60 A, 100 A and 200 A to match the shore supply
REPAIR COST
About $300 (€260) for a 30 A and $490 (€430) for a 60 A fail-safe isolator, marine retailer listing, plus fitting

Plug a boat into shore power and the green earth wire connects its propeller, shaft and through-hulls to the shore earth, and through it to every other boat plugged in on the dock. DEI Marine describes the result as a galvanic corrosion cell: dissimilar metals in seawater, joined by a wire. The least noble metal loses, and on a busy dock that's often your anodes first and your underwater metals after.

What an isolator does

A galvanic isolator sits in series with the shore earth wire. It blocks the small DC currents that drive galvanic corrosion and still passes AC fault current, so the earth does its safety job. The alternative is an isolation transformer, which separates the boat from shore power altogether and costs more.

Under the revised ABYC A-28, a fail-safe isolator has been confirmed by an independent laboratory to keep working, or leave a permanent earth path, if it fails, and needs no monitor. Units come rated 30 A, 50/60 A, 100 A and 200 A to match the shore supply.

How a surveyor checks it

Trace the green earth from the shore power inlet. An isolator is usually close behind the inlet; read its label for the rating and any fail-safe marking. No isolator and no transformer is the finding.

Then look for the evidence. Anodes that waste fast, owners renewing them more than once a season, and corrosion on underwater metals point to current through the shore earth. Worst is the earth wire disconnected to stop the wastage. That swaps a corrosion problem for an electrical safety one.

No galvanic isolator: example findings

The same defect written up at each grade, the way Axsail writes it from what the surveyor says on board. The grade follows what was found, so use these as wording, then grade what you see.

ELECTRICALA
Shore power inlet, AC earth

Green earth conductor from the shore power inlet disconnected at the AC panel, apparently to stop anode wastage. No galvanic isolator or isolation transformer fitted.

Recommendation: Reconnect the shore power earth before shore power is next used, and fit a fail-safe galvanic isolator in the earth conductor.

ELECTRICALB
Shore power system

30 A shore power fitted with no galvanic isolator or isolation transformer. Propeller anode about 70 percent wasted; owner reports anodes renewed each season.

Recommendation: Fit a fail-safe galvanic isolator rated for the shore supply in the earth conductor near the inlet, within 12 months.

ELECTRICALC
Galvanic isolator, behind the shore power inlet

Galvanic isolator fitted, older unit with no fail-safe marking and no monitor.

Recommendation: Check the isolator with a meter at the next maintenance period, and consider a fail-safe unit when it is replaced.

ASafety. Safety or compliance deficiency. Fix before the vessel is next underway.
B12 months. Deficiency that needs timely attention. Fix within about 12 months.
CRoutine. Note or observation, cosmetic or maintenance. Routine maintenance at the owner's convenience.

What fitting one costs

Job Reported cost
Fail-safe galvanic isolator, 30 A About $300 (€260), marine retailer listing
Fail-safe galvanic isolator, 60 A About $490 (€430), marine retailer listing
Fitting near the shore power inlet Electrician's time
Isolation transformer More; priced per supply

For a boat with two 30 A inlets, DEI Marine notes a single 50/60 A isolator can replace two 30 A units.

Photos to take

The shore power inlet and the wiring behind it, the isolator label or the gap where one should be, the anodes and any corroded underwater metals. With Axsail, say what you see as you take them and they go on the electrical finding.

Writing it up

State the shore supply, whether an isolator or transformer is fitted and its rating, whether the earth is connected, and the anode condition. If the earth is disconnected, say so first and grade it A. A missing isolator is a B on its own.

Frequently asked

Does my boat need a galvanic isolator?

If it plugs into shore power, it's worth having. The shore earth wire connects your boat's underwater metals to the shore earth and to every other boat plugged in, which makes a galvanic cell. An isolator in that wire blocks the small DC currents and still passes fault current, so the earth keeps doing its safety job.

Why not just disconnect the shore power earth?

Because the earth is what makes a fault safe. Without it, a fault in the boat's AC system can make metal on board live, and leaking current in the water near the boat is a danger to swimmers. Surveyors grade a disconnected earth as a safety finding.

How much does a galvanic isolator cost?

A marine retailer lists ProMariner's fail-safe isolator at about $300 (€260) for 30 A and $490 (€430) for 60 A. Fitting is usually a short job near the shore power inlet, priced by the electrician.

Is a zinc anode enough without an isolator?

An anode protects the boat's own metals. It isn't sized for current arriving through the shore earth from other boats on the dock, so on a busy marina it can waste much faster than expected.

What is a fail-safe galvanic isolator?

One that an independent laboratory has confirmed will keep working, or leave a permanent earth path, if it fails. Under the revised ABYC A-28, a fail-safe isolator needs no monitor.

Your full survey report, minutes after the walk-round

Dictate as you inspect. Axsail builds the findings and the report for your signature

Start free

Standards it's judged against

ABYC

American Boat and Yacht Council standards

What the American Boat and Yacht Council is, how its standards are written and kept up to date, why they're voluntary but still decide survey findings, how to get the full text, and the standards surveyors cite most.

What surveyors check
ABYC A-28

Galvanic Isolators

What ABYC A-28 covers for galvanic isolators on boats with shore power, what fail-safe means, the ratings, what a surveyor checks and how to cite A-28 in a finding.

What surveyors check

Related findings

Findings library
ELECTRICAL

Missing overcurrent protection

Why an unfused battery cable is a fire risk, the ABYC E-11 rule surveyors check against, which fuse types suit which battery banks, what the fix costs and three example findings graded A, B and C.

How to find and write it up
UNDERWATER GEAR

Seized seacocks

Why a seacock that won't close is a safety finding, how surveyors check seacocks and through-hulls, the ABYC strength test a ball valve on a through-hull can fail, replacement costs and three example findings graded A, B and C.

How to find and write it up
ELECTRICAL

Unsecured batteries

What ABYC E-10 asks of battery installations, why a loose battery is a safety finding, boxes versus straps, insulated terminals and three example findings graded A, B and C.

How to find and write it up
ELECTRICAL

Lithium batteries without a BMS

What ABYC E-13 asks of lithium battery systems on boats, why a battery management system is required, what a surveyor checks on a lithium install and three example findings graded A, B and C.

How to find and write it up
ELECTRICAL

Shore power reverse polarity

What reverse polarity on a boat's shore power means, why breakers stop protecting you, the ABYC reverse polarity indicator, how a surveyor tests it and three example findings graded A, B and C.

How to find and write it up
ELECTRICAL

Stray current corrosion

How stray current corrosion shows up on a boat, why anodes can't stop it, where it comes from on board and at the marina, how it's tested and three example findings graded A, B and C.

How to find and write it up

Report templates with this finding

FREE TEMPLATE · WORD

Pre-purchase survey

A free Word template for a yacht pre-purchase survey report: every section explained, example wording, the sea trial and valuation, and example findings graded A, B and C.

Open template
FREE TEMPLATE · WORD

Insurance survey

A free Word template for a condition and valuation survey report for boat insurance: each section explained, the insurer's requirements, market and replacement value, and example findings graded A, B and C.

Open template

Related guides

INSPECTION CHECKLISTS · 7 MIN

Yacht survey checklist: what a surveyor inspects, system by system

The full boat and yacht survey checklist, from hull and keel to rig, engine, gas and safety kit, and what changes between a pre-purchase and an insurance survey.