Axsail
FAULT CODES · CHARGERS, INVERTERS AND BATTERIES

Victron Phoenix inverter error codes: what the red alarm LED and the green inverter LED are telling you

UPDATED 16 NOVEMBER 2026 · 2 FINDINGS · 1 SOURCES

Victron Phoenix inverter error codes from Victron's manual: each LED pattern for overload, battery voltage, temperature and DC ripple, and the restarts.

AT A GLANCE
Victron Phoenix Inverter Smart
MAKER
Victron Energy
COVERS
Phoenix Inverter Smart models from 1600 VA to 5000 VA
WHERE THE CODE SHOWS
On the green Inverter LED and red Alarm LED of the unit, and as warning or alarm messages in the VictronConnect app
CHECK FIRST
Battery cable size and tightness, the battery voltage at the inverter's terminals, and the AC load

Victron Phoenix inverter error codes on the Phoenix Inverter Smart are shown by two LEDs: the red Alarm LED says which protection it is, and the green Inverter LED says whether it's still a warning or the inverter has shut down. Green steady means a warning. Green blinking with a fast double pulse means the inverter has switched off on that alarm. The patterns below are from Victron's Phoenix Inverter Smart manual.

LED patterns

Red Alarm LED Green LED steady: warning Green LED fast double pulse: alarm, inverter off
On Overload warning: AC load above the rating Overload alarm: shut down, no automatic restart
Slow blinking Low battery voltage warning Low battery voltage alarm
Fast blinking High battery voltage warning High battery voltage alarm
Double pulse High temperature warning High temperature alarm
Fast single pulse High DC ripple warning DC ripple alarm

Other states from the same table: all LEDs off means the inverter is switched off, has its remote on/off loop open or has no DC supply. Green blinking with the yellow ECO LED on is ECO mode searching for a load. Green and red both blinking means a firmware update is running or has failed.

What to check for each alarm

Alarm Victron's checks
Overload Reduce the AC load. Motors and pumps with a high start-up current can trip it
Low battery voltage Charge the battery, turn AC loads off, check the cable connections are tight and the cables thick enough
High battery voltage The battery bank wiring, and chargers, alternators or solar chargers with a faulty regulator
High temperature Reduce the AC load or move the inverter somewhere better ventilated
DC ripple Loose DC connections or cables that are too thin, and that the fuses and battery isolators work

Restarts and lock-outs

Most alarms clear themselves. After a low battery, high temperature or high battery shutdown, the inverter waits at least 30 seconds and restarts when the condition has gone. Overload and DC ripple are different: after 3 restarts and a fourth trip within 30 seconds, the inverter stays off until someone switches it off and on again. Victron adds that continuous high DC ripple shortens the inverter's life.

For surveyors

A DC ripple or low battery alarm on an inverter that's otherwise healthy usually points to the cables and the battery, so look at cable size against the inverter's rating, the fuse close to the battery and the terminal lugs. Note the alarm history in VictronConnect if the owner can connect. With Axsail, say "Phoenix inverter, red alarm LED fast single pulse, DC ripple, 25 mm² cables on a 3000 VA unit" and it goes into the electrical section.

Findings to look for on Victron Phoenix Inverter Smart

Each page shows how the defect is found, what decides the grade and example findings written up at A, B and C.

ELECTRICAL

Missing overcurrent protection

Why an unfused battery cable is a fire risk, the ABYC E-11 rule surveyors check against, which fuse types suit which battery banks, what the fix costs and three example findings graded A, B and C.

How to find and write it up
ELECTRICAL

Old batteries

How to read a battery's age from its date code, how long AGM batteries are expected to last, the resting voltage and load test a battery maker gives, the signs a bank is worn out, and three example findings graded A, B and C.

How to find and write it up

Frequently asked

Why is the red light flashing on my Victron inverter?

On a Phoenix Inverter Smart with the green LED on, a slowly blinking red Alarm LED is a low battery voltage warning, fast blinking is high battery voltage, a double pulse is high temperature and a fast single pulse is high DC ripple. If the green LED is also blinking with a fast double pulse, the inverter has shut down on that alarm.

What does DC ripple mean on a Victron inverter?

Victron's manual says high DC ripple is usually caused by loose DC cable connections or DC wiring that's too thin, which makes the voltage drop over the battery cables. After 3 restarts with ripple still too high, the inverter stays off until it's switched off and on again.

Will a Victron inverter restart after a low battery alarm?

Yes, after at least 30 seconds once the battery voltage rises above the low battery restart level. After three restarts followed by another low battery shutdown within 30 seconds, it stays off until it's switched off and on or the battery is recharged.

How do I reset a Victron Phoenix inverter after an overload?

Remove the cause of the overload, then switch the inverter off and back on. Victron says it shuts down after 3 restarts followed by another overload within 30 seconds of restarting, and then won't restart by itself.

Your full survey report, minutes after the walk-round

Dictate as you inspect. Axsail builds the findings and the report for your signature

Start free

More fault codes

All fault codes
CHARGERS, INVERTERS AND BATTERIES

Victron MultiPlus and Quattro (VE.Bus)

Victron VE.Bus error codes for MultiPlus and Quattro inverter chargers: error 11 relay test, error 24 switch-over protection, and which codes keep the system off.

Look up a code
CHARGERS, INVERTERS AND BATTERIES

Victron BatteryProtect

Victron BatteryProtect and Smart BatteryProtect error codes: E1 to E4 on every model, E0 and E5 to E8 on the Smart versions, and the P2 and P3 warnings.

Look up a code
CHARGERS, INVERTERS AND BATTERIES

Victron Lynx Smart BMS

Victron Lynx Smart BMS error codes from Victron's manual: what 1 to 14 red LED flashes mean, the W-B warnings, A-B alarms, E-B errors and blown fuse alarms.

Look up a code
CHARGERS, INVERTERS AND BATTERIES

Victron MPPT solar chargers

Victron MPPT error codes from Victron's own list: battery and PV errors, Err 67 BMS connection lost, Err 116, and which codes reset by themselves.

Look up a code
CHARGERS, INVERTERS AND BATTERIES

Victron Orion XS DC-DC charger

Victron Orion XS error codes from Victron's manual: battery temperature, terminal overheated, BMS connection lost (error 67) and the 150 to 161 warnings.

Look up a code
CHARGERS, INVERTERS AND BATTERIES

Victron Cerbo GX and GX devices

Victron Cerbo GX error codes from Victron's manual: #42 storage corrupt, #46 data partition full, #48 DVCC firmware, #51 MK3 update and #60 MFD connection.

Look up a code

Standards to check against

ABYC E-11

AC and DC Electrical Systems on Boats

What ABYC E-11 covers on a boat's AC and DC systems, the rules surveyors check most often, from the 7 inch battery fuse rule to the reverse polarity indicator, and how to cite E-11 in a finding.

What surveyors check