Victron Orion XS error codes show in the VictronConnect app or on a GX device as a number and a short description. Errors stop the charger, and warnings reduce or pause charging while it carries on. Most clear themselves once the cause has gone. The ones that don't, such as 21, 28 and 119, need the wires disconnected or the settings restored. The list below is from Victron's Orion XS manual.
Error codes
| Code | Meaning | Resets itself | What to check |
|---|---|---|---|
| 1 | Battery temperature too high | Yes | Without a battery sensor, a hot charger reads as a hot battery |
| 2 | Battery voltage too high | Yes | Other charging equipment on the battery, or a charge controller fault |
| 17 | Controller overheated despite reduced current | Yes | Ambient temperature and how the unit is mounted for cooling |
| 21 | Current sensor issue | No | Disconnect and reconnect all wires. If it stays, a dealer |
| 26 | Terminal overheated | Yes | Wire type and strands, and tighten the terminal bolts |
| 27 | Charger short circuit | Yes | If it doesn't clear, disconnect all power for 3 minutes |
| 28 | Power stage issue | No | Disconnect and reconnect all wires. If it persists, the unit is probably faulty |
| 33 | Input voltage too high | Yes | Clears once the input voltage drops |
| 67 | BMS connection lost | When the link returns | The BMS cable and the BMS control setting |
| 116 | Calibration data lost | Active and not working: faulty unit. Only in the history: ignore | |
| 117 | Incompatible firmware | Retry the firmware update | |
| 119 | Settings data lost | No | Factory defaults, 3 minutes without power, reconfigure |
| 120 | Internal supply voltage error | No | Check the installation and restart. If it persists, faulty |
| 122 | History data corrupted | No | Clear the history in VictronConnect |
Warnings
| Code | Meaning | What happens |
|---|---|---|
| 150 | Battery temperature too high | Output drops to 12 V until the battery cools |
| 151 | Battery temperature too low | Charging stops to protect a lithium battery |
| 160 | Current derated, controller hot | Current reduced until the charger cools |
| 161 | Short circuit detected | Over-current on the battery side. Disconnect power for 3 minutes if it stays |
Victron points out that warning 151 is a protection working as set, and the low temperature limit can be adjusted by the installer.
Error 67 and lithium systems
With a BMS in charge, error 67 is the one to understand. Fifteen seconds after the BMS messages stop, the Orion XS lowers its output to 12 V, which VictronConnect shows as a jump from bulk to float. The error itself appears only after 3 minutes, and only while the charger wants to charge. When the link comes back, it returns to bulk.
For surveyors
The Orion XS sits between the alternator side and a house bank, often lithium. Look at the cable runs at both ends and the terminal bolts, since errors 26 and 1 both trace back to heat. If it's under BMS control, check the BMS link and compare the installation with the lithium batteries without a BMS finding. With Axsail, say "Orion XS, error 26 in history, terminal bolt on the output loose" as you photograph it.