Victron Cerbo GX error codes come from two places. Codes shown as GX Error #42 to #60 are the GX device's own. Any other code on the screen comes from a connected device, usually a VE.Bus code from a MultiPlus or Quattro, or a charger code from a solar charger, and those have their own lists. The GX codes below are from Victron's Cerbo GX manual.
GX device error codes
| Code | Meaning | Victron's solution |
|---|---|---|
| #42 | Storage corrupt | Return for repair or replacement. Can't be fixed by firmware or in the field |
| #46 | Data partition full | Free space below 10%, usually from third-party apps such as Node-RED or Signal K |
| #47 | Data partition issue | Internal storage likely damaged. Contact the dealer or installer |
| #48 | DVCC with incompatible firmware | Bring every device up to the firmware the DVCC chapter lists |
| #49 | Grid meter not found | ESS setups with an external grid meter: check wiring and configuration |
| #51 | MK3 firmware needs update | Start the update from the MultiPlus or Quattro device menu |
| #60 | Could not connect to the GX device | Reboot the GX device or the MFD |
Victron's FAQ adds that with #42, settings can't be saved and revert to defaults after every reboot.
Codes from other devices
| What the screen shows | Where it comes from | Look it up in |
|---|---|---|
| VE.Bus error with a number | MultiPlus or Quattro inverter-charger | Victron VE.Bus error codes |
| Error number on a solar charger | SmartSolar or BlueSolar MPPT | Victron MPPT error codes |
| Error number on a DC-DC charger | Orion XS | Victron Orion XS error codes |
| Alarm from the battery system | Lynx Smart BMS | Victron Lynx Smart BMS error codes |
DVCC and error #48
DVCC is distributed voltage and current control, run from the GX device. Victron's manual notes that newer Venus OS versions switch DVCC on automatically for some lithium batteries, so an older system that updates can show #48 when one device's firmware is behind. Its advice is to have an installer bring all the devices up to date.
MK3 update and #51
The MK3 is the interface inside the GX device that talks to the inverter-charger. Victron says the one-off update can briefly restart the system, in around 5% of cases by its data, so the inverter-charger may cycle off and on. Do it when nothing on board depends on inverter power.
For surveyors
A GX device gives a quick history of the whole electrical system. Open the alarm and notification list on the screen or in VRM if the owner has access, and photograph any active code. A #42 means the settings on display may not be the ones the installer chose. With Axsail, say "Cerbo GX showing error 42, battery settings at defaults" as you photograph the screen.