Side-Power thruster error codes: the Sleipner fault numbers 1 to 39 for thrusters, retracts and hydraulics

UPDATED 16 NOVEMBER 2026 · 2 FINDINGS · 1 SOURCES

Side-Power thruster error codes from Sleipner's legacy fault code list: motor overcurrent, overtemp, low voltage, IPC error, fuse blown and the retract faults.

AT A GLANCE
Sleipner Side-Power thrusters
MAKER
Sleipner (Side-Power)
COVERS
Side-Power thrusters, retract units and hydraulic systems on S-Link with older firmware, including the PPC520, PPC800, PPC820 and PPC840 controllers
WHERE THE CODE SHOWS
As an error number and text on an S-Link control panel with a display, with an optional external buzzer
CHECK FIRST
Battery voltage at the thruster while it runs, the main fuse and the S-Link cables

Side-Power thruster error codes are numbered faults from 1 to 39 that an S-Link control panel shows as text, such as "Motor Overtemp" or "Low Voltage". Sleipner keeps this numbering for older products and older firmware. Several, such as an IPC error or a critical error, need a service technician. The meanings below are from Sleipner's legacy fault code list.

Thruster fault codes

No. Error shown Meaning Sleipner's action
1 Motor Overcurrent Motor current too high Service by authorised personnel, reset or switch the controller off and on
2 Motor Overtemp Motor over 120 °C Wait until below 110 °C. Resets itself
3, 4 Controller Overtemp Controller over 80 °C Wait until below 45 °C
5 Low Voltage Below 8.00 V on 12 V, 12.00 V on 24 V, motor running Recharge the battery, reset or switch off and on
6 Thermoswitch Thermal switch open Let the thruster cool. Resets itself
7 IPC Error Motor relay fault Turn off the main switch, service by authorised personnel
8 Critical Error Controller output fail Controller must go for service
9 Low Motor Current Thruster uses no power Check the thruster connections or the motor
10 Motor Contactor No current on the motor relay coil Relay connections, short circuit or a dead relay
12 No Communication No communication with the device S-Link cables and power connections
13 Motor Temp Sensor Temperature sensor failed Open circuit on the motor's temperature sensor
14 Supply Voltage Fault No power Power connections
15 Fuse Blown Fuse blown Replace the fuse, or check the main cables haven't been swapped
16 Manual Override Main switch manually overridden Pull the main switch
30 Temperature Warning Motor temperature getting high Resets itself
35 Warning Low Voltage Below 9.30 V on 12 V, 17.50 V on 24 V, motor running Warning that comes before error 5

Retract and hydraulic codes

No. Error shown Meaning
17 Motion OUT Fault Retract obstructed while deploying. Go slower or into deeper water and retry
18 Motion IN Fault Retract obstructed while retracting. Override the main switch, clear it, retry
19 Actuator Fault Actuator not getting power
20 Pos. Sensor Fault Retract position sensor failed
21 In Service Mode DIP switch 4 is on in the retract control box
22 High Oil Temp Hydraulic oil above 75 °C. Check the cooling pump runs
23 Low Oil Level Top up the hydraulic tank
39 Interlock No S-Link communication between the controller and the retract controller

Most of the other codes up to 38 belong to hydraulic power packs and stabilisers on larger installations.

For surveyors

Sleipner measures both low voltage limits with the motor running, so voltage drop in the cables counts as much as the battery's charge. Check the cable run against the thruster's installation manual and look for a fuse close to the battery as ABYC E-11 requires. Have the thruster run in both directions and note any code on the panel. With Axsail, say "bow thruster, Warning Low Voltage after 5 seconds, thruster battery 12.1 V at rest" as you photograph the panel.

Findings to look for on Sleipner Side-Power thrusters

Each page shows how the defect is found, what decides the grade and example findings written up at A, B and C.

ELECTRICAL

Missing overcurrent protection

Why an unfused battery cable is a fire risk, the ABYC E-11 rule surveyors check against, which fuse types suit which battery banks, what the fix costs and three example findings graded A, B and C.

How to find and write it up
UNDERWATER GEAR

Depleted anodes

When sacrificial anodes need replacing, zinc, aluminium or magnesium for your water, what anodes that aren't wasting mean, what a surveyor checks and three example findings graded A, B and C.

How to find and write it up

Frequently asked

What does low voltage mean on a Side-Power thruster?

Sleipner's fault list gives error 35, warning low voltage, below 9.30 V on a 12 V thruster or 17.50 V on 24 V while the motor runs. Error 5, the low voltage alarm, is below 8.00 V on 12 V or 12.00 V on 24 V. Recharge the battery, then reset or switch the device off and on.

What is an IPC error on a Sleipner thruster?

Error 7, a motor relay fault. Sleipner says to turn off the thruster's battery main switch and have the thruster serviced by authorised personnel.

Why does my Side-Power thruster say motor overtemp?

Error 2: the motor temperature has been over 120 °C. It resets automatically once the motor has cooled below 110 °C. Error 6, thermoswitch, is the same cool-down wait on thrusters with a thermal switch.

What does fuse blown mean on a Side-Power thruster?

Error 15. Sleipner says to replace the fuse, or check whether the main cable from the battery and the main cable to the thruster have been swapped.

Your full survey report, minutes after the walk-round

Dictate as you inspect. Axsail builds the findings and the report for your signature

Start free

More fault codes

All fault codes
ONBOARD SYSTEMS

Vetus DBPPJA thruster panel

Vetus bow thruster error codes on the DBPPJA proportional joystick panel, from Vetus's manual: overheated, overloaded, limiting, low supply and network faults.

Look up a code
ONBOARD SYSTEMS

Secop (Danfoss) BD35F and BD50F fridge compressors

Boat fridge compressor error codes for the Secop (formerly Danfoss) BD35F and BD50F from Secop's own instructions: what 1 to 6 LED flashes mean and what to check.

Look up a code
ONBOARD SYSTEMS

Dometic marine air conditioning

Dometic marine air conditioner fault codes from Dometic's manuals: HPF, LPF, ASF, LAC, PLF and FIL, the failsafe levels and the lockout reset.

Look up a code
ONBOARD SYSTEMS

Schenker ZEN watermakers

Schenker watermaker alarms on the ZEN touch panel, from Schenker's manual: System blocked, Control cable, Bad water quality, the bypass warnings and the valve reset.

Look up a code
ENGINES AND OUTBOARDS

Honda BF115 to BF250 outboards

Honda outboard alarm codes from Honda's owner's manuals: the ACG, malfunction, oil pressure and overheat indicators, each buzzer pattern and what to do.

Look up a code
ENGINES AND OUTBOARDS

Tohatsu MFS 75A to 115A outboards

Tohatsu outboard warning codes from Tohatsu's owner's manual for the MFS 75A, 90A and 115A: each buzzer and lamp pattern with its remedy, and the ESG speed limits.

Look up a code

Standards to check against

ABYC E-11

AC and DC Electrical Systems on Boats

What ABYC E-11 covers on a boat's AC and DC systems, the rules surveyors check most often, from the 7 inch battery fuse rule to the reverse polarity indicator, and how to cite E-11 in a finding.

What surveyors check