Side-Power thruster error codes are numbered faults from 1 to 39 that an S-Link control panel shows as text, such as "Motor Overtemp" or "Low Voltage". Sleipner keeps this numbering for older products and older firmware. Several, such as an IPC error or a critical error, need a service technician. The meanings below are from Sleipner's legacy fault code list.
Thruster fault codes
| No. | Error shown | Meaning | Sleipner's action |
|---|---|---|---|
| 1 | Motor Overcurrent | Motor current too high | Service by authorised personnel, reset or switch the controller off and on |
| 2 | Motor Overtemp | Motor over 120 °C | Wait until below 110 °C. Resets itself |
| 3, 4 | Controller Overtemp | Controller over 80 °C | Wait until below 45 °C |
| 5 | Low Voltage | Below 8.00 V on 12 V, 12.00 V on 24 V, motor running | Recharge the battery, reset or switch off and on |
| 6 | Thermoswitch | Thermal switch open | Let the thruster cool. Resets itself |
| 7 | IPC Error | Motor relay fault | Turn off the main switch, service by authorised personnel |
| 8 | Critical Error | Controller output fail | Controller must go for service |
| 9 | Low Motor Current | Thruster uses no power | Check the thruster connections or the motor |
| 10 | Motor Contactor | No current on the motor relay coil | Relay connections, short circuit or a dead relay |
| 12 | No Communication | No communication with the device | S-Link cables and power connections |
| 13 | Motor Temp Sensor | Temperature sensor failed | Open circuit on the motor's temperature sensor |
| 14 | Supply Voltage Fault | No power | Power connections |
| 15 | Fuse Blown | Fuse blown | Replace the fuse, or check the main cables haven't been swapped |
| 16 | Manual Override | Main switch manually overridden | Pull the main switch |
| 30 | Temperature Warning | Motor temperature getting high | Resets itself |
| 35 | Warning Low Voltage | Below 9.30 V on 12 V, 17.50 V on 24 V, motor running | Warning that comes before error 5 |
Retract and hydraulic codes
| No. | Error shown | Meaning |
|---|---|---|
| 17 | Motion OUT Fault | Retract obstructed while deploying. Go slower or into deeper water and retry |
| 18 | Motion IN Fault | Retract obstructed while retracting. Override the main switch, clear it, retry |
| 19 | Actuator Fault | Actuator not getting power |
| 20 | Pos. Sensor Fault | Retract position sensor failed |
| 21 | In Service Mode | DIP switch 4 is on in the retract control box |
| 22 | High Oil Temp | Hydraulic oil above 75 °C. Check the cooling pump runs |
| 23 | Low Oil Level | Top up the hydraulic tank |
| 39 | Interlock | No S-Link communication between the controller and the retract controller |
Most of the other codes up to 38 belong to hydraulic power packs and stabilisers on larger installations.
For surveyors
Sleipner measures both low voltage limits with the motor running, so voltage drop in the cables counts as much as the battery's charge. Check the cable run against the thruster's installation manual and look for a fuse close to the battery as ABYC E-11 requires. Have the thruster run in both directions and note any code on the panel. With Axsail, say "bow thruster, Warning Low Voltage after 5 seconds, thruster battery 12.1 V at rest" as you photograph the panel.