Vetus bow thruster error codes on the DBPPJA proportional panel are shown by the red LED, the four direction LEDs and a buzzer. The top two direction LEDs flash for a bow thruster fault and the bottom two for a stern thruster fault, and the red LED's rhythm says which fault it is. When the fault clears, the red LED goes off and the buzzer gives two short beeps. The patterns below are from Vetus's DBPPJA user manual.
Fault patterns
| Red LED | Blue LED | Buzzer | Direction LEDs | Meaning |
|---|---|---|---|---|
| Fast flashing | Once, di-dah-di-di-dah | Top two flash faster | Bow thruster overheated | |
| Flashing | Once, di-dah-di-di-dah | Top two flash faster | Bow thruster overloaded | |
| Double flash | Once, di-dah-di-di-dah | Top two flash faster | Bow thruster limiting | |
| Flashing | Fast flashing | Once, di-dah-di-di-dah | Top two flash faster | Bow thruster supply low |
| Off | Once, di-di | Top two off | Bow thruster was overheated, overloaded or limiting | |
| Top left and bottom right flash fast | Panel supply low | |||
| All four double flash | Joystick broken | |||
| On | Disconnected from the network |
The stern thruster gives the same patterns on the two bottom direction LEDs.
Normal states
| Blue LED | Buzzer | Meaning |
|---|---|---|
| Flashing for 6 seconds | Short beeps for 6 seconds | Child lock: press on/off again within 6 seconds |
| On | Once, dah-di-dah | Panel on, bow and stern thrusters ready |
| Double flash | This panel is off while another panel controls the thruster |
A single short beep means the joystick button has been pressed. To switch off, hold the on/off button until all LEDs go out and the buzzer gives di-di-di-dah-dah.
Overheating and overload
The DBPPJA manual lists the faults without temperature or current thresholds, which sit with the thruster. It separates two kinds of low supply: the thruster's supply, shown with the blue LED flashing fast, and the panel's own feed, shown on the direction LEDs alone. Measure the voltage at the thruster while it runs to tell a flat battery from voltage drop in the cables.
For surveyors
Run the thruster both ways for a few seconds each and watch the panel. A low supply pattern with the engine off is worth recording, then repeated with the engine running and the alternator charging. With Axsail, say "bow thruster, Vetus panel red LED flashing with blue fast, supply low, thruster battery 11.9 V" as you photograph the panel.