Schenker watermaker alarms on the ZEN touch panel are colour-coded messages. A red alarm such as System blocked stops the unit, and it has to be reset with the STOP button. An orange warning such as Bypass warning means the unit keeps making water with some protection switched off. System blocked comes from a hydraulic block, and when air has left the hydraulic valve stuck, the manual valve reset clears it. The messages below are from Schenker's ZEN 30 12/24 V touch manual.
Alarms (red, unit stops)
| Message | Meaning | What Schenker says to do |
|---|---|---|
| SYSTEM BLOCKED | Hydraulic block, pump switched off for safety | Run the reset procedure and look for the hydraulic cause. If only the signal pressure switch is faulty, restart with the bypass on |
| CONTROL CABLE | Lost connection | Check the cable between the remote panel and the computer box |
| BAD WATER QUALITY | Salinity too high after a divert cycle (optional probe) | The unit has stopped the pump group |
| High pressure | Pump pressure above 9.5 bar | Shown when the high pressure switch trips |
Warnings and status messages
| Message | Meaning |
|---|---|
| BYPASS WARNING | Running in bypass mode, with some safety functions disabled |
| DIV. VALVE BY-PASS | Running without the salinity probe, so all water goes to the tank |
| DIVERT TO DISCHARGE | Salinity too high, water diverted overboard |
| SYSTEM STOP | Standby because the fresh water tank is full |
| S = OK, MED or BAD | Quality of the water being made |
The bypass is cancelled automatically after one production cycle. Schenker asks for it to be used only when the signal pressure switch has failed, or during the chemical wash shut-down.
The reset procedure
If the watermaker sucks air, the automatic hydraulic valve can stop in a central position. On the next start the pressure rises without cycling and the computer switches the pump off after a few seconds. Schenker says it doesn't damage the system. The manual's illustrated reset includes opening the reset valve and slightly opening the depressurisation valve, screwing the positioner knob clockwise until it stops (normally at least 18 turns) and back, closing the reset valve, restarting, and closing the depressurisation valve after a few seconds. Follow its pictures step by step.
Filters and maintenance
The manual asks for the strainer to be checked and cleaned every 5 days, and for the unit to run only in reasonably clear water, away from coral reefs where particles are abrasive. After a filter change, a new installation or a chemical wash, run the automatic start-up procedure to purge the air.
For surveyors
If the owner allows it and the water is clean, run the watermaker and note the messages with the salinity reading. Check the seawater inlet valve, the strainer and the hose runs, and whether the panel shows a bypass warning. With Axsail, say "Schenker ZEN 30, System blocked within a minute, strainer clear, bypass warning showing" as you photograph the panel.