A boat fridge compressor error code on a Secop BD35F or BD50F is a number of LED flashes, from 1 to 6, that the compressor's electronic unit gives when it stops. One flash is low battery voltage, the commonest cause on a boat. The others point to the fan, the motor, overheating or the thermostat. Secop says it was formerly known as Danfoss Compressors, which is why many boat owners still call it a Danfoss compressor. The meanings below are from Secop's instructions for the 12/24 V electronic units.
What the flashes mean
| Flashes | Error | What to check |
|---|---|---|
| 1 | Battery protection cut-out | The voltage is outside the cut-out setting: battery charge and voltage drop in the supply cable |
| 2 | Too many start attempts, or fan over-current | Too many compressor or fan starts in a short time, or a fan drawing more than 0.5 A on average |
| 3 | Motor start error | Rotor blocked, or a pressure difference above 5 bar in the system |
| 4 | Minimum motor speed error | System too heavily loaded: the motor can't hold about 1,850 rpm |
| 5 | Thermal cut-out of the electronic unit | Unit running too hot from a heavy load or high ambient temperature: ventilation |
| 6 | Thermostat failure | The NTC thermistor is short-circuited or disconnected |
Each flash lasts a quarter of a second, followed by a pause, and the sequence repeats every 4 seconds.
Battery protection settings
Secop's standard battery protection cuts the compressor out at 10.4 V and back in at 11.7 V on a 12 V system, and at 22.8 V and 24.2 V on 24 V. Other settings can be chosen with a resistor on the unit. The instructions also give minimum cable sizes by length between battery and electronic unit, from 2.5 mm² for up to 2.5 m on 12 V. A cable that's too thin drops the voltage at the electronic unit as the compressor starts, so check the voltage there as well as at the battery.
Fitting the LED
The LED is optional: a 10 mA LED wired between the + and D/I terminals of the electronic unit. Many fridges don't have one fitted, so a quiet compressor gives no clue until it's added, or until the unit is read with Secop's TOOL4COOL software.
For surveyors
A fridge that cuts out on 1 flash is usually an electrical finding, the supply cable or the battery, rather than a fridge fault. Measure the voltage at the electronic unit with the compressor running and note the cable size. With Axsail, say "fridge compressor, 1 flash, 11.2 V at the electronic unit with compressor running" and it's written up with the cable check as the recommendation.