Boat fridge compressor error codes: what 1 to 6 flashes mean on a Secop (Danfoss) BD35F or BD50F

UPDATED 16 NOVEMBER 2026 · 1 FINDINGS · 3 SOURCES

Boat fridge compressor error codes for the Secop (formerly Danfoss) BD35F and BD50F from Secop's own instructions: what 1 to 6 LED flashes mean and what to check.

AT A GLANCE
Secop (Danfoss) BD35F and BD50F fridge compressors
MAKER
Secop, formerly known as Danfoss Compressors
COVERS
BD35F, BD50F, BD35K and BD80CN compressors with the 12/24 V DC electronic units 101N0242, 101N0680 and 101N0682, used in many boat fridges and cool boxes
WHERE THE CODE SHOWS
As flashes of an LED wired between the + and D/I terminals of the electronic unit, if one is fitted, or in Secop's TOOL4COOL software
CHECK FIRST
Battery voltage at the electronic unit and the cable size from the battery, then ventilation round the compressor

A boat fridge compressor error code on a Secop BD35F or BD50F is a number of LED flashes, from 1 to 6, that the compressor's electronic unit gives when it stops. One flash is low battery voltage, the commonest cause on a boat. The others point to the fan, the motor, overheating or the thermostat. Secop says it was formerly known as Danfoss Compressors, which is why many boat owners still call it a Danfoss compressor. The meanings below are from Secop's instructions for the 12/24 V electronic units.

What the flashes mean

Flashes Error What to check
1 Battery protection cut-out The voltage is outside the cut-out setting: battery charge and voltage drop in the supply cable
2 Too many start attempts, or fan over-current Too many compressor or fan starts in a short time, or a fan drawing more than 0.5 A on average
3 Motor start error Rotor blocked, or a pressure difference above 5 bar in the system
4 Minimum motor speed error System too heavily loaded: the motor can't hold about 1,850 rpm
5 Thermal cut-out of the electronic unit Unit running too hot from a heavy load or high ambient temperature: ventilation
6 Thermostat failure The NTC thermistor is short-circuited or disconnected

Each flash lasts a quarter of a second, followed by a pause, and the sequence repeats every 4 seconds.

Battery protection settings

Secop's standard battery protection cuts the compressor out at 10.4 V and back in at 11.7 V on a 12 V system, and at 22.8 V and 24.2 V on 24 V. Other settings can be chosen with a resistor on the unit. The instructions also give minimum cable sizes by length between battery and electronic unit, from 2.5 mm² for up to 2.5 m on 12 V. A cable that's too thin drops the voltage at the electronic unit as the compressor starts, so check the voltage there as well as at the battery.

Fitting the LED

The LED is optional: a 10 mA LED wired between the + and D/I terminals of the electronic unit. Many fridges don't have one fitted, so a quiet compressor gives no clue until it's added, or until the unit is read with Secop's TOOL4COOL software.

For surveyors

A fridge that cuts out on 1 flash is usually an electrical finding, the supply cable or the battery, rather than a fridge fault. Measure the voltage at the electronic unit with the compressor running and note the cable size. With Axsail, say "fridge compressor, 1 flash, 11.2 V at the electronic unit with compressor running" and it's written up with the cable check as the recommendation.

Findings to look for on Secop (Danfoss) BD35F and BD50F fridge compressors

Each page shows how the defect is found, what decides the grade and example findings written up at A, B and C.

ELECTRICAL

Missing overcurrent protection

Why an unfused battery cable is a fire risk, the ABYC E-11 rule surveyors check against, which fuse types suit which battery banks, what the fix costs and three example findings graded A, B and C.

How to find and write it up

Frequently asked

Why does my boat fridge compressor flash once?

On a Secop BD35F or BD50F electronic unit, 1 flash is a battery protection cut-out: the voltage is outside the cut-out setting. Secop's standard settings cut out at 10.4 V and back in at 11.7 V on 12 V, and 22.8 V and 24.2 V on 24 V. Check the battery and the voltage drop in the supply cable.

What do 3 flashes mean on a Danfoss or Secop fridge?

Motor start error. Secop says the rotor is blocked or the pressure difference in the refrigeration system is too high, more than 5 bar. A compressor restarted too soon after stopping can see this.

How do I read the Secop flash code?

Each flash lasts a quarter of a second. After the flashes there's a pause, and the sequence repeats every 4 seconds. Count the flashes in one sequence. The LED is optional, so many fridges need one wired in between the + and D/I terminals first.

What does 5 flashes mean on a BD35F?

Thermal cut-out of the electronic unit. Secop says it runs too hot when the refrigeration system is too heavily loaded or the ambient temperature is high, so check the ventilation round the compressor and condenser.

Your full survey report, minutes after the walk-round

Dictate as you inspect. Axsail builds the findings and the report for your signature

Start free

More fault codes

All fault codes
CHARGERS, INVERTERS AND BATTERIES

Victron BatteryProtect

Victron BatteryProtect and Smart BatteryProtect error codes: E1 to E4 on every model, E0 and E5 to E8 on the Smart versions, and the P2 and P3 warnings.

Look up a code
ONBOARD SYSTEMS

Dometic marine air conditioning

Dometic marine air conditioner fault codes from Dometic's manuals: HPF, LPF, ASF, LAC, PLF and FIL, the failsafe levels and the lockout reset.

Look up a code
ONBOARD SYSTEMS

Sleipner Side-Power thrusters

Side-Power thruster error codes from Sleipner's legacy fault code list: motor overcurrent, overtemp, low voltage, IPC error, fuse blown and the retract faults.

Look up a code
ONBOARD SYSTEMS

Vetus DBPPJA thruster panel

Vetus bow thruster error codes on the DBPPJA proportional joystick panel, from Vetus's manual: overheated, overloaded, limiting, low supply and network faults.

Look up a code
ONBOARD SYSTEMS

Schenker ZEN watermakers

Schenker watermaker alarms on the ZEN touch panel, from Schenker's manual: System blocked, Control cable, Bad water quality, the bypass warnings and the valve reset.

Look up a code
ENGINES AND OUTBOARDS

Honda BF115 to BF250 outboards

Honda outboard alarm codes from Honda's owner's manuals: the ACG, malfunction, oil pressure and overheat indicators, each buzzer pattern and what to do.

Look up a code

Standards to check against

ABYC E-11

AC and DC Electrical Systems on Boats

What ABYC E-11 covers on a boat's AC and DC systems, the rules surveyors check most often, from the 7 inch battery fuse rule to the reverse polarity indicator, and how to cite E-11 in a finding.

What surveyors check