Fischer Panda generator fault codes on the PMS 5.5e are text messages on the control panel. A warning, dark text on a light background, means a reading is approaching its limit, and it goes away when the reading recovers. A shutdown, light text on dark, means the limit has been reached, and the generator stops soon after. The messages below are from Fischer Panda's PMS 5.5e manual.
Common messages and fixes
| Message | Likely cause from the manual | What to do |
|---|---|---|
| Start attempt failed | No speed signal: low fuel, clogged fuel filter, failed fuel pump | Add fuel, replace the filters or the pump |
| Max. No. of failed starts | Start attempts used up | Stop trying: water collects in the exhaust. Contact a dealer |
| Exh. m. temp. high | No or restricted sea water flow | Open the sea water valve, clean the strainer, check water in the exhaust, replace the impeller |
| Cyl. h. temp. high | Overload, sea water flow, low oil, low coolant, air in the coolant | Reduce the load, fix the water flow, top up and bleed the coolant |
| Coil temp. is high | Overload, alternator air intake blocked | Reduce the load, clear the air intake |
| Oil pressure is low | Low engine oil, sensor not connected | Fill to the full mark, check the sensor connection |
| Starter batt. voltage low | Poor battery connection or low battery | Check both connections, measure and charge |
| Unexpected engine stop | Oil pressure and speed lost without a stop command | Low fuel, fuel filter, fuel pump |
| Water leak sensor trigger | Water detected in the generator capsule | Look inside the capsule for the source |
Other control panel messages
| Message | Meaning |
|---|---|
| Actuator fault | Speed control actuator calibration failed |
| Batt. voltage too low | Starter battery below what the control system allows |
| Check/bleed coolant system | Cylinder head temperature above the maximum |
| CHECK FIRE SYSTEM | Remote stop contacts open, if enabled for a fire system |
| Fuel pump is in S.C. | Short circuit on the fuel pump output |
| Glow plugs in SC | Short circuit on the glow plug output |
| Lost inverter connection | Engine controller no longer talking to the inverter |
| Output power high | Output above the programmed maximum |
| Restart delay | Minimum time since the last shutdown hasn't passed |
| Tank level is low | Generator fuel tank low |
Acknowledging and restarting
Press Alarm Mute to silence the alarm. A shutdown message stays until Start/Stop is pressed. Fischer Panda's caution is that operation outside the limits damages the generator, so the cause has to be fixed before restarting. It also says repeated failed starts can fill the exhaust with water until it enters the engine through the exhaust manifold.
For surveyors
Run the generator under load for long enough to warm up and watch the panel. Look at the sea water strainer, the exhaust outlet's water flow and the capsule for water, and compare the installation with the generator exhaust finding. With Axsail, say "Fischer Panda 5.5, Exh. m. temp. high after 12 minutes at 3 kW, strainer basket fouled" and it goes into the engine survey report.