Webasto Air Top Evo 40 and Evo 55 fault codes run from F00 to F19. A combination timer shows them as F codes up to F15 and as "- -" above that. A rotary control or Multi Control flashes them: five short flashes, then count the long ones. Failed starts, flame aborts and overheats are counted, and enough of them lock the heater out. The codes below are from Webasto's Air Top Evo 40 / 55 workshop manual.
Fault codes
| Code | Fault | What Webasto says to check |
|---|---|---|
| F00 | Control unit defective, heater lock-out or room temperature sensor defective | Clear the lock-out (below), otherwise the control unit |
| F01 | No start: no flame even after a restart | Fuel supply, exhaust temperature sensor deposits, evaporator mount |
| F02 | Flame abort: flame went out and didn't relight | Same checks as F01 |
| F03 | Undervoltage or overvoltage | Below 10.5 V or 20.5 V for 20 seconds, or above 16 V or 32 V for 6 seconds |
| F04 | Premature flame detection | The exhaust temperature sensor |
| F07 | Fuel pump defective | Wiring and fuel pump, open or short circuit |
| F08 | Drive motor open circuit, short circuit, overload or blocked | Blockage, then the fan magnets and the drive unit |
| F09 | Glow plug defective | The glow plug |
| F10 | Overheating | The hot air guide: kinked line, closed outlet, dirty blow-out sensor |
| F14 | Blow-out temperature sensor defective | The sensor |
| F16 | Exhaust temperature exceeded | Combustion air and exhaust clear, CO2 setting, soot in the heat exchanger |
| F17 | Exhaust temperature sensor defective | Replace the sensor |
| F18 | Setpoint generator defective | Wiring and the control element |
| F19 | Sensor plausibility incorrect | The exhaust and blow-out temperature sensors |
The manual lists F05, F06, F11, F12, F13 and F15 as not available on the Air Top Evo.
Diagnostic codes
A workshop reading the heater with Webasto Thermo Test sees a two-character code under each F code. Examples from the manual: 02 no flame after restart, 03 flame out during operation, 84 undervoltage, 04 overvoltage, 88 open circuit in the fuel pump, 19 short circuit in the glow plug, 06 overheated at the blow-out sensor and 4F upper exhaust temperature limit exceeded.
Lock-out
The control unit counts failures, and the heater locks out when a counter reaches its limit: 9 failed starts, 5 overheats, 3 flame aborts after restarts, or 5 other faults. A clean start into control mode resets the counters. To clear a lock-out, switch on, pull the fuse, refit it after more than 2 seconds and switch on again. Webasto adds that if serious faults such as overheating keep happening, the heater locks out permanently and needs a Webasto-trained technician.
For surveyors
Webasto's checks for F01 and F02 lead to the fuel supply and the exhaust, and for F10 to the hot air ducting, which on a boat often runs behind lockers. Check the exhaust skin fitting and that the cabin has a working CO alarm, as the no carbon monoxide alarm finding sets out. With Axsail, say "Webasto Air Top Evo 40, three long flashes, F03, heater on the same battery as the windlass" as you film the controller.