Webasto heater error codes on the Air Top 2000 STC run from F00 to F15. A control with a display shows the code as text, and a control without one flashes it: the number of long flashes is the fault number. Most codes point to air, fuel or the glow plug, and F12 means the heater has locked itself out. The codes below are from Webasto's operating instructions and the troubleshooting section of its workshop manual.
F codes and blink codes
| Code | Fault | What to check |
|---|---|---|
| F00 | Control unit defective | Rapid flashing on a control without a display. The W-bus wiring and control element, then the control unit |
| F01 | No start | Air intake and exhaust, fuel system, fuel pump, glow plug |
| F02 | Flame failure | The flame went out and didn't relight. Same checks as F01 |
| F03 | Supply voltage too high or too low | The system voltage. Charge the battery |
| F04 | Flame detected before combustion | Air intake, exhaust, fuel system, glow plug |
| F05 | Flame sensor interruption | A break or short in the flame sensor circuit |
| F06 | Temperature sensor interruption | The internal or external temperature sensor circuit |
| F07 | Fuel pump interruption | A break or short in the fuel pump circuit |
| F08 | Combustion air fan short circuit or blocked | The fan motor and both fan wheels for snagging |
| F09 | Glow plug interruption | The glow plug or ignition unit circuit |
| F10 | Heater overheated | Hot and cold air ducts clear, then air intake, exhaust and fuel |
| F11 | Overheat sensor interruption | The overheating sensor circuit |
| F12 | Heater lock-out | Reset the lock-out, then read the other stored faults |
| F14 | Overheat sensor gradient too low at start | Position of the overheating sensor, fuel supply |
| F15 | Setpoint potentiometer interruption | The setpoint sensor circuit |
The operating instructions say codes above F15 show as "- -" on a display.
Hex codes from the diagnostic tool
A workshop reading the heater with Webasto Thermo Test sees two-digit hex codes, with more detail than the F codes. Examples from the workshop manual: 02 no start, 03 flame failure, 06 overheated, 07 heater lock-out, 0A glow plug short circuit, 12 W-bus communication failure, 15 combustion air fan blocked, 84 operating voltage too low and 88 fuel pump interruption.
Resetting a lock-out
The heater locks out when the fault counter passes 10, the false start counter passes 7 or the overheating counter passes 20, according to the workshop manual. To reset: switch the heater on, pull fuse F1 for at least 10 seconds, switch the heater off, refit the fuse and switch on. If it locks out again, the cause from the earlier codes is still there.
Webasto also asks owners to run the heater every 4 weeks, so its moving parts don't seize, and to have it checked by a professional at the start of each heating season.
For surveyors
A heater code is a reason to look at the exhaust run and the hull outlet as much as at the heater. Webasto's own warning is that a blocked exhaust or combustion air path can make the heater unsafe, so check there's a working CO alarm in the cabin, as the no carbon monoxide alarm finding sets out. With Axsail, say "Webasto heater, F10 on the controller, hot air duct crushed behind the saloon locker" as you photograph it.