Eberspächer heater fault codes on the Airtronic S2 and M2 come in two forms: a flashing code from 1 to 15 on the heater, and a longer P000 code that the EasyStart Pro, EasyStart Web or EasyScan tool shows. Flame cutouts, failed starts and overheating account for most of them, and enough of those in a row lock the heater until it's cleared with a diagnostic control. The codes below are from Eberspächer's Airtronic S2 and M2 repair instructions.
Flashing codes
| Flashes | Error | What to check |
|---|---|---|
| 0 | No fault, normal operation | |
| 1 | Locking due to overheating | The control box locked after too many overheating events: find the cause, then clear it with a diagnostic control |
| 2 | Overvoltage cut-off | The supply voltage and charging system |
| 3 | Undervoltage cut-off | The battery and the heater's supply cables |
| 4 | Glow plug defective | Glow plug and its wiring |
| 5 | Burner motor defective | The combustion air blower |
| 6 | Invalid configuration | The control box setup |
| 7 | Safety time exceeded | No flame within the start time: exhaust, combustion air, fuel |
| 8 | Overheating | Air throughput, ducts and the overheating sensor |
| 9 | Metering pump defective | The fuel metering pump and its wiring |
| 10 | External temperature sensor or setpoint transmitter defective | The sensor and its cable |
| 11 | Combination sensor defective | The combined flame and overheating sensor |
| 12 | Flame cutout | Exhaust, combustion air, fuel supply, fuel filters |
| 13 | Too many exceedances of safety time 1 | Repeated failed starts: fuel and air supply |
| 14 | Control box defective | The control box |
| 15 | Other errors | Needs EasyScan diagnosis |
The P000 fault codes
A diagnostic control shows the same faults as P000 codes, with the older LIN number in brackets. A few from the repair instructions:
| Code | Fault | Repair instructions say |
|---|---|---|
| P000114 (014) | Possible risk of overheating | The overheating sensor has reached at least 80 °C. Check the sensor and its cables |
| P000115 (012) | Overheating, software threshold | Over 125 °C at the overheating sensor. Check air throughput and the sensor |
| P000116 (017) | Overheating, hardware threshold | Over 130 °C. Same checks as P000115 |
| P00011A (015) | Operating lock-out, heater locked | Too many overheating events. Fix the cause, then clear the lock with a diagnostic control |
| P000120 (064), P000121 (065) | Flame sensor interruption or short circuit | The sensor and its cable |
| P000125 to P00012A | Flame cutout, at start or by output range | Exhaust and combustion air, fuel quantity and supply, a new fuel filter |
The repair instructions add that after a flame cutout the heater tries to restart up to 5 times, and a successful restart deletes the fault from the display. A code that keeps coming back is a real fault.
Reading the stored faults
The control box stores up to 20 faults, 10 active and 10 stored. The EasyScan tool, EasyStart Pro, EasyStart Web and EasyStart Remote+ can read them and clear the lock. A Remote+ shows "Err" for the current fault and lets you scroll stored faults F1 to F5. A plain switch on the S+ input can't be used for diagnosis.
For surveyors
Repeated flame cutouts and lock-outs usually trace back to the exhaust run, the combustion air intake or the fuel supply, so look at the hull exhaust outlet and the fuel standpipe as well as the heater. Check the cabin has a working CO alarm, as in the no carbon monoxide alarm finding. With Axsail, say "Eberspächer heater, flashes 12 times, soot at the exhaust skin fitting" and it's written up in the heating section.