An in-water survey (IWS) examines a ship's bottom while it's afloat, by divers or an ROV with a surveyor watching, and can take the place of every other dry docking. The rules come from the classification societies' IACS UR Z3, the MCA's MGN 546 for UK ships and Transport Canada's TP 11249. All three ask the same thing: the survey afloat must tell the surveyor what a dry docking would.
Intervals
| Rule | Bottom examinations | What may be afloat |
|---|---|---|
| IACS UR Z3 | Two in each five-year special survey period, one at the special survey, never more than 36 months apart | The alternate examination, under Z3.3 |
| MGN 546, cargo ships | Two in any five-year period, intervals not over 36 months | One of them, by IWS |
| MGN 546, seagoing passenger ships | Every year | The years without an out of water inspection |
| MGN 546, passenger ships on categorised waters | Out of water at every passenger survey, unless an extended period is agreed | The years between, with out of water at least twice in five years |
| TP 11249 | Alternate surveys in dry dock | Every other one, for non-passenger vessels with permission from Ship Safety |
IACS UR Z3 lets the interval stretch for ships in fresh water and for some harbour and non-self-propelled craft, and reminds owners that SOLAS may still require shorter intervals.
Who's eligible
- Age: MGN 546 normally stops at 15 years, or 20 years for categorised-waters passenger ships. UR Z3 asks for special consideration from 15 years, and ESP ships of 15 years and over must dry dock.
- Ship types: MGN 546 covers seagoing passenger ships, other ships except tankers and bulk carriers over 15 years, and passenger ships on categorised waters. TP 11249 excludes tankers, Inland Waters vessels and 80% Ocean Modulus vessels.
- Hull preparation: MGN 546 asks for an approved cathodic protection system and hull markings at regular intervals, for example every 5 m, so the diver knows where they are.
- Entry: TP 11249 says the vessel must first dry dock to enter the in-water programme, with three copies of the hull plans.
How the survey is done
UR Z3 sets the core: sheltered water with weak currents, a clean hull, visibility good enough to judge plating, appendages and welds, equipment tested beforehand, an approved in-water survey firm, and good two-way communication between the surveyor and the divers. MGN 546 adds the figures: current under 0.5 knot, stop if visibility is generally below 5 metres, cover the entire hull and its fittings, and survey the hull above the waterline at the same time. It accepts an ROV as an alternative to, or in addition to, divers.
The master or owner's representative declares any damage or contact since the last dry docking, per both MGN 546 and TP 11249. For the Marshall Islands registry, IIMS reports that the request goes to the recognised organisation at least four weeks ahead, with that declaration.
What the report must contain
MGN 546 asks for a diver's report cross-referenced to the video, photographs and annotated plans. Unless the surveyor says otherwise, it covers plating, weld seams, corrosion, distortion, indentations, cracks, paint, every hull opening and sea chest, stabiliser boxes, thruster tunnels, A-frames and P-brackets, propellers, liners, seals, rudders, bearings and their bolts. The records are compared at the next dry docking. If the survey shows damage that needs early attention, UR Z3 lets the surveyor order the ship into dry dock.
For surveyors
On an in-water survey the surveyor directs the dive by voice and the diver reports back the same way, so most of the report is already being said out loud. With Axsail the surveyor or ROV pilot talks each area through as it's filmed, stills go on the right finding, and the draft follows the underwater hull inspection report template. The method itself is on underwater hull inspection; the US Coast Guard's version is UWILD.