A bilge pump is the last line between a leak and a sinking at the mooring. H-22 is the standard for the electric pump system: the pump, its switch and wiring, the inlet, the discharge and the alarm that tells someone it can't keep up.
What it covers
ABYC lists H-22 as Electric Bilge Pump Systems. In our words: how electric bilge pumps are rated, installed, wired and switched, where their inlets and discharges go, and when a high-water alarm is needed.
What surveyors check against it
Rating. Practical Sailor reports ABYC has pumps rated at a head of 1 metre and 3 metres of hose. Real installations with longer runs and more lift move less.
Inlet. Placed so bilge water can be removed with the boat at rest, Practical Sailor notes.
Discharge. Above the waterline so water can't siphon back in. Where that isn't possible, H-22 asks for a vented loop and a properly installed seacock.
Alarm. On boats with enclosed accommodation, a high-water alarm. D'Antonio calls it a requirement for ABYC compliance and suggests its switch sit no more than 2 inches above the pump's float switch.
Wiring. The pump's circuit protected like any other, with the fuse within 7 inches of the source under ABYC E-11.
Then test it: lift the float or flood the switch and see the pump start. See bilge pump float switch failure.
Citing it in a finding
"Fit a high-water bilge alarm, ABYC H-22, with its switch above the primary pump's float switch." Record which pumps are fitted, how each was tested and where each discharges.