What is a galvanic isolator on a boat? What it does and what a surveyor checks

UPDATED 10 NOVEMBER 2026 · 3 SOURCES

A galvanic isolator protects a boat on shore power from galvanic corrosion through the earth wire. What it does, why the earth can't just be cut, fail-safe units under ABYC A-28, and the survey check.

DEFINITION
Galvanic isolator

A device in the shore power earth wire that blocks the small DC currents that corrode a boat's underwater metal, while still passing fault current so the earth stays safe.

When you plug into shore power, the green earth wire connects your boat's underwater metal to the shore earth, and through it to every other boat on the dock. Different metals in the same water, connected by a wire, make a battery. Small DC currents flow, and your anodes, then your propeller, pay for it.

Cutting the earth would stop it and take away the safety of the AC system. A galvanic isolator sits in the earth wire instead and blocks the small DC voltages while still passing fault current. Units come rated 30 A, 50/60 A, 100 A and 200 A to match the supply. ABYC A-28 covers them, and under its revised text a fail-safe unit needs no monitor.

What a surveyor checks

The earth wire traced from the shore power inlet to the isolator, and its label: the rating, and whether it's fail-safe or monitored. An isolation transformer does the same job. The anodes and underwater metal for fast wasting. A boat on shore power with neither is a finding. A boat with the earth disconnected is a safety one.

In the report

"Shore power, 30 A inlet, no galvanic isolator or isolation transformer. Anodes heavily wasted. Fit a fail-safe isolator rated for the supply." See no galvanic isolator.

Frequently asked

Does my boat need a galvanic isolator?

If it plugs into shore power, it's worth having. The shore earth links your boat's underwater metal to every other boat plugged in, which makes a galvanic cell. The isolator blocks the small currents and still passes fault current.

How much does a galvanic isolator cost?

A marine retailer lists ProMariner's fail-safe isolator at about $300 (€260) for 30 A and $490 (€430) for 60 A, plus fitting.

Findings to write up

ELECTRICAL

No galvanic isolator

How the shore power earth links your boat's underwater metals to every boat on the dock, what a galvanic isolator does, what ABYC A-28 asks for, what one costs and three example findings graded A, B and C.

How to find and write it up
UNDERWATER GEAR

Depleted anodes

When sacrificial anodes need replacing, zinc, aluminium or magnesium for your water, what anodes that aren't wasting mean, what a surveyor checks and three example findings graded A, B and C.

How to find and write it up
ELECTRICAL

Stray current corrosion

How stray current corrosion shows up on a boat, why anodes can't stop it, where it comes from on board and at the marina, how it's tested and three example findings graded A, B and C.

How to find and write it up

Standards it's judged against

ABYC A-28

Galvanic Isolators

What ABYC A-28 covers for galvanic isolators on boats with shore power, what fail-safe means, the ratings, what a surveyor checks and how to cite A-28 in a finding.

What surveyors check

Related terms

Glossary
UNDERWATER GEAR

Anode

A block of zinc, aluminium or magnesium fitted to a boat's underwater metal that corrodes in its place, so the propeller, shaft and fittings last.

ELECTRICAL

ELCI

A breaker on a boat's shore power that trips when current leaks out of the AC system, usually at 30 mA, so the boat can't put dangerous current into the water.

ELECTRICAL

Battery management system

The electronics that watch a lithium battery's voltage, current and temperature and disconnect it before it's damaged.

ELECTRICAL

Battery switch

The heavy rotary switch that connects or isolates a boat's batteries, often marked 1, 2, Both and Off.

ELECTRICAL

Bonding system

Wires, usually green, that connect a boat's underwater metal fittings to each other, the anodes and the DC negative.

ELECTRICAL

Reverse polarity

A shore power fault where the hot and neutral wires are swapped, so breakers switch the neutral and leave circuits live.

Your full survey report, minutes after the walk-round

Dictate as you inspect. Axsail builds the findings and the report for your signature

Start free