A windlass that won't work is usually starved of power. Lewmar's manual says most windlass problems are electrical, and its troubleshooting starts with whether there's voltage at the control switch, then at the motor. A click with no movement, or slow hauling, usually means voltage is being lost in the cables or connections before it reaches the motor. The checks below are from Lewmar's owner's manual for its V2 and V3 windlasses; the same logic applies to most electric windlasses, but use your own maker's figures.
How it's wired
The windlass motor draws heavy current, so it has its own circuit from the battery, through an isolator and a circuit breaker, to a solenoid or control box and the motor. Lewmar requires the breaker to protect the wiring and the motor if it stalls under an excessive load; it has to be reset by hand after it trips. The foot switches or handheld remote only switch the solenoid.
Fails to operate
Follow Lewmar's chart from the battery towards the motor:
- Voltage at the input to the control switch? If none, Lewmar lists the battery isolator off, the breaker tripped, a blown fuse, or a dead or disconnected battery.
- Voltage at the switch outputs with the switch at forward, then reverse? If none, the control switch has failed.
- Voltage across the motor leads with the windlass on? Lewmar's figure is 13.5 volts on a 12 volt system.
- Low, under 11 volts? There's a severe voltage drop. See below.
- Correct, above 11 volts, and the anchor isn't fouled? Then Lewmar says to replace the motor. Check first that the windlass isn't simply overloaded.
Clicks or runs slowly
Lewmar's sluggish operation chart:
| Cause | What to do |
|---|---|
| Overload | Ease the load, motor towards the anchor, and make sure the battery is well charged |
| Severe voltage drop | Check for undersized cables and poor or corroded connections |
| Resistance in the isolator or solenoid | Feel them for heat while the windlass runs |
| Defective motor | Replace it |
Lewmar's limit is a voltage drop from cable resistance of no more than 10%, and it sizes cables by the total run from the battery and back, which it warns is far longer than the boat. Running the windlass on low voltage for long periods destroys the motor.
Using it so it keeps working
- Motor towards the anchor while hauling. Lewmar recommends using the engine to help, but not motoring over and past the anchor, which can let the rode damage the topsides.
- Secure the rode independently of the windlass when anchored and when stowed. A slack gypsy drive cap and an unsecured rode let the chain pay out on its own.
- Leave the fallsafe pawl engaged when the anchor is stowed, to stop it dropping under way.
- Inspect the gypsy regularly; Lewmar calls it a high wear item.
- Don't touch the motor after use. It stays hot for some time.
If power fails, Lewmar's manual recovery versions can haul in with a winch handle in the gypsy cap after the breaker is switched off. The gypsy drum version doesn't have manual recovery as standard and needs a kit.
For surveyors
Run the windlass both ways and note how it sounds under load. Look at the motor terminals and the breaker, and record the voltage at the motor if you can. With Axsail, say "windlass hauls slowly, 10.6 volts at the motor under load, solenoid warm, terminals corroded" and it goes on the pre-purchase survey report. The anchor chain size tool covers the chain the gypsy is matched to.