Axsail
BOAT SYSTEMS · DECK GEAR

Windlass not working: no voltage, clicking or sluggish, and the checks Lewmar gives

UPDATED 17 NOVEMBER 2026 · 1 SOURCES

Why an anchor windlass stops working or only clicks: the isolator, breaker and fuse, voltage at the switch and motor, voltage drop, then the motor itself.

AT A GLANCE
Windlass not working
SYMPTOM
Nothing happens at the switch, it clicks without turning, runs slowly under load, or the chain pays out on its own
CHECK FIRST
Battery isolator on, the windlass breaker not tripped, and the fuse intact
USUAL CAUSES
An isolator off or a tripped breaker, a flat battery, voltage drop from undersized or corroded cables, a failed control switch or solenoid, a failed motor, an overload
READ WITH
The windlass maker's manual for its cable sizes and troubleshooting charts

A windlass that won't work is usually starved of power. Lewmar's manual says most windlass problems are electrical, and its troubleshooting starts with whether there's voltage at the control switch, then at the motor. A click with no movement, or slow hauling, usually means voltage is being lost in the cables or connections before it reaches the motor. The checks below are from Lewmar's owner's manual for its V2 and V3 windlasses; the same logic applies to most electric windlasses, but use your own maker's figures.

How it's wired

The windlass motor draws heavy current, so it has its own circuit from the battery, through an isolator and a circuit breaker, to a solenoid or control box and the motor. Lewmar requires the breaker to protect the wiring and the motor if it stalls under an excessive load; it has to be reset by hand after it trips. The foot switches or handheld remote only switch the solenoid.

Fails to operate

Follow Lewmar's chart from the battery towards the motor:

  1. Voltage at the input to the control switch? If none, Lewmar lists the battery isolator off, the breaker tripped, a blown fuse, or a dead or disconnected battery.
  2. Voltage at the switch outputs with the switch at forward, then reverse? If none, the control switch has failed.
  3. Voltage across the motor leads with the windlass on? Lewmar's figure is 13.5 volts on a 12 volt system.
  4. Low, under 11 volts? There's a severe voltage drop. See below.
  5. Correct, above 11 volts, and the anchor isn't fouled? Then Lewmar says to replace the motor. Check first that the windlass isn't simply overloaded.

Clicks or runs slowly

Lewmar's sluggish operation chart:

Cause What to do
Overload Ease the load, motor towards the anchor, and make sure the battery is well charged
Severe voltage drop Check for undersized cables and poor or corroded connections
Resistance in the isolator or solenoid Feel them for heat while the windlass runs
Defective motor Replace it

Lewmar's limit is a voltage drop from cable resistance of no more than 10%, and it sizes cables by the total run from the battery and back, which it warns is far longer than the boat. Running the windlass on low voltage for long periods destroys the motor.

Using it so it keeps working

  • Motor towards the anchor while hauling. Lewmar recommends using the engine to help, but not motoring over and past the anchor, which can let the rode damage the topsides.
  • Secure the rode independently of the windlass when anchored and when stowed. A slack gypsy drive cap and an unsecured rode let the chain pay out on its own.
  • Leave the fallsafe pawl engaged when the anchor is stowed, to stop it dropping under way.
  • Inspect the gypsy regularly; Lewmar calls it a high wear item.
  • Don't touch the motor after use. It stays hot for some time.

If power fails, Lewmar's manual recovery versions can haul in with a winch handle in the gypsy cap after the breaker is switched off. The gypsy drum version doesn't have manual recovery as standard and needs a kit.

For surveyors

Run the windlass both ways and note how it sounds under load. Look at the motor terminals and the breaker, and record the voltage at the motor if you can. With Axsail, say "windlass hauls slowly, 10.6 volts at the motor under load, solenoid warm, terminals corroded" and it goes on the pre-purchase survey report. The anchor chain size tool covers the chain the gypsy is matched to.

Findings to look for

Each page shows how the defect is found, what decides the grade and example findings written up at A, B and C.

ELECTRICAL

Battery switch

What goes wrong with a boat's 1-2-Both battery switch, why turning it through Off with the engine running can kill the alternator, the flicker test for a worn switch, what a surveyor checks and three example findings graded A, B and C.

How to find and write it up
HULL AND STRUCTURE

Leaking deck hardware

How leaking stanchion bases, cleats and tracks let water into a cored deck, the spider cracks that show poor backing, what Practical Sailor recommends for backing plates, how rebedding works, and three example findings graded A, B and C.

How to find and write it up

Frequently asked

Why is my windlass not working?

Lewmar says most windlass problems are electrical. If there's no voltage at the control switch, the battery isolator is off, the breaker has tripped, a fuse has blown, or the battery is flat or disconnected. If there's voltage at the switch but none at its outputs, the switch has failed; if the motor gets correct voltage and the anchor isn't fouled, the motor is at fault.

Why does my windlass click but not work?

A click means the control circuit is working but the motor isn't turning. Check the voltage across the motor leads with the windlass on. Lewmar says it should be 13.5 volts on a 12 volt system; below 11 volts points to a severe voltage drop from undersized cables, poor or corroded connections, or resistance in the isolator or solenoid.

What voltage does a windlass need?

Lewmar gives 13.5 volts as the proper voltage on a 12 volt system and 26.5 volts on 24 volts, and warns that constant low voltage will destroy the motor. Cable voltage drop should not exceed 10%.

Why does my anchor chain run out by itself?

Lewmar puts it down to not securing the rode combined with a slack gypsy drive cap. Tighten the cap with the winch handle and always secure the rode independently of the windlass when it isn't in use.

Your survey report, minutes after the sea trial

Dictate as you inspect. Axsail builds the findings and the report for your signature

Start free

More boat systems

All boat systems
ELECTRICAL AND PROTECTION

Battery not charging

Why a boat battery won't charge while running or on shore power: the voltages to expect, the alternator's fuses, relays and belt, the charger, and failed cells.

Read the checks
ENGINES AND FUEL

Outboard won't start

Why an outboard won't start and what to check in order: battery, neutral, kill switch lanyard, fuse, then fuel and spark when it turns over but won't fire.

Read the checks
ENGINES AND FUEL

Mercury outboard won't start

Why a Mercury outboard won't start or crank, from Mercury's troubleshooting chart: lanyard at RUN, neutral, the fuse, and priming after running dry.

Read the checks
ENGINES AND FUEL

Yamaha outboard won't start

Why a Yamaha outboard won't start, from Yamaha's own chart: neutral, the lanyard lock plate, choke, air vent screw, fuel, plugs and the 5-second crank rule.

Read the checks
ENGINES AND FUEL

Boat won't start

Why a boat won't start and what to check: battery switch, voltage and connections, neutral and kill switch, the starter if it clicks, fuel if it cranks.

Read the checks
ENGINES AND FUEL

Fuel gauge and sending unit

Why a boat fuel gauge stops working and how to test it: the gauge, the sender wire, the ground, and the 33 to 240 ohm sending unit, with each sender type.

Read the checks

Report templates

FREE TEMPLATE · WORD

Pre-purchase survey

Free Word template for a recreational boat or yacht pre-purchase survey report: each section explained, with example wording and findings graded by urgency.

Open template
FREE TEMPLATE · WORD

Charter and fleet condition

A free Word template for a charter or fleet yacht condition report: safety equipment, systems, inventory, damage since the last check, readings and sign-off, with example findings graded A, B and C.

Open template