USCG uninspected vessel requirements are the equipment rules in 46 CFR Subchapter C for commercial boats that don't need a Certificate of Inspection, such as six-pack charters and workboats. Part 25 sets what they carry, from life jackets to fire extinguishers, and Part 24 sets who it applies to. Nobody issues a certificate, so it's the owner's job to keep the boat compliant. Everything below is from the current eCFR text.
Who it covers
Subchapter C applies to US-flag and foreign-flag vessels listed in 46 CFR 2.01-7 as uninspected, except vessels only on inland waters that aren't navigable waters of the US, vessels laid up and out of commission, and public vessels. For charter, the line is the passenger count: up to 6 passengers on a boat under 100 GT is a six-pack; more needs a Certificate of Inspection.
Equipment requirements
| Item | 46 CFR | Requirement |
|---|---|---|
| Life jackets | 25.25-5 | An approved wearable life jacket of a suitable size for each person; approval series 160.055, 160.155, 160.176 or 160.255 when carrying passengers for hire or 40 ft and over |
| Lifebuoy | 25.25-5 | At least one approved lifebuoy from 26 ft; three on uninspected passenger vessels of 100 GT and over |
| Life jacket lights | 25.25-13 | Approved light on each life jacket on ocean, coastwise and Great Lakes voyages |
| Reflective tape | 25.25-15 | At least 200 sq cm of approved retroreflective material on each side of each life jacket |
| Distress signals | 25.25-19 | Visual distress signals to 33 CFR 175 |
| Fire extinguishers | 25.30-20 | 5-B portables by length: one under 26 ft, two from 26 to under 40 ft, three from 40 to 65 ft, one fewer with a fixed system in the machinery space |
| Backfire flame control | 25.35-1 | On every inboard gasoline engine |
| Ventilation | 25.40-1 | At least two cowled ducts, intake and exhaust, for engine and fuel tank compartments on boats using fuel with a flashpoint of 110°F or less, except open boats |
| Navigation lights | 25.10-3 | Certified to ABYC A-16 by a Coast Guard-listed laboratory and labelled |
EPIRBs
| Vessel | 46 CFR | EPIRB |
|---|---|---|
| Uninspected passenger vessel under 100 GT | 25.26-10 | Not required |
| Uninspected passenger vessel of 100 GT and over, beyond 3 miles | 25.26-10 | Float-free, automatic Category 1, 406 MHz |
| Other manned commercial vessel, 36 ft and over, on the high seas or 3 miles off the Great Lakes | 25.26-20 | Float-free, automatic Category 1, 406 MHz |
| Under 36 ft, or with builder-certified buoyancy | 25.26-20 | Manual Category 2 at the helm, or a Category 1 |
Any required EPIRB is tested monthly and its battery replaced after use or before the expiry date, under 25.26-50.
Cooking and heating with passengers
On a boat carrying passengers for hire, 46 CFR 25.45-2 allows LPG or CNG cooking only if the system meets ABYC A-1 for LPG or A-22 for CNG, or chapter 6 of NFPA 302. The gas must be odorised. LPG cylinders are marked and mounted to ABYC A-1.
For surveyors
An uninspected commercial boat has no certificate to tell you what's required, so work from the use, the length and the voyage. The USCG boat inspection checklist follows the same order. With Axsail, dictate each item with its count and date, "five-B extinguishers, two, one gauge in the red, no fixed system", and it becomes a graded finding.